Refer to the table below to perform inspection when the equipment is operating poorly.
If you cannot resolve a problem after inspecting the equipment, request repair at the
retail outlet where the equipment was purchased.
Symptom
Possible Causes
Remedy
Starter motor does
not start.
1
.
Battery has a low charge.
2
.
Battery is deteriorated.
1
.
Recharge the battery.
2
.
Replace the battery.
Engine does not
start.
1
.
Fuel lever is
"CLOSE" .
2
.
No fuel
3
.
Water or foreign material is
mixed in with the fuel.
4
.
Blown fuse
1
.
Turn the fuel lever to
"OPEN".
2
.
Add fuel.
3
.
Drain water from and clean the
fuel tank and fuel strainer.
4
.
Replace the fuse.
Engine starts but
quickly stops.
1
.
Insufficient oil
2
.
Overheating of water
temperature
3
.
Battery recharging fault
1
.
Add oil.
2
.
Comply with rated outputs/Add
cooling water.
3
.
Repair.
Black or white
smoke is
continuously
exhausted from
the muffler.
1
.
Overloaded
1
.
Comply with the rated output.
Engine does not
stop.
1
.
Stop solenoid fault
1
.
Turn the fuel lever to
"CLOSE"
to stop the engine and repair.
Weak welding arc
1
.
Single/Dual selector is set to
"DUAL" .
2
.
Frequency selector is set to
"50Hz" .
3
.
Wrong Output control dial
position
4
.
Faulty cable connection
5
.
Improper cable
(excessively thin)
6
.
Faulty connection with base
material
7
.
Using simultaneously as AC
power source
8
.
Welding cable short circuit
1
.
Set to
"SINGLE" .
2
.
Set to
"60Hz" .
3
.
Turn the dial clockwise
4
.
Connect securely.
5
.
Replace with cable according to
"Welding Cable Selection".
6
.
Connect securely.
7
.
Do not use as AC power source.
8
.
Remove the cause of the short
circuit.
Strong welding arc
1
.
Single/Dual selector is set to
"SINGLE" .
2
.
Wrong Output control dial
position
1
.
Set to
"DUAL" .
2
.
Turn the dial counterclockwise
Weld output
cannot be
adjusted.
1
.
Remote controller is connected. 1
.
Disconnect the remote
controller. Or, adjust using the
remote controller.
No AC power
output
1
.
Breaker is
"OFF" .
1
.
Turn the breaker to
"ON" .
AC power output is
weak.
1
.
Wrong frequency
2
.
The current of devices using
the equipment exceed the
rated current.
3
.
Using simultaneously for
welding.
1
.
Check frequency
2
.
Refer to
"Usable Device
Capacities
" .
3
.
Stop welding.