- 23 -
<<<<
Note
>>>>
•
Do not crank the starter motor for 15 seconds or more continuously.
•
If repeating starter switch operation, wait 30 seconds or more between operations.
•
After the engine starts, do not turn the starter switch to "START" during operation.
■
Restarting after Stopping due to Running Out of Fuel
The equipment includes an automatic air-bleeding device. You can easily restart
the engine according to the following procedures even if the engine stops due to
running out of fuel.
1) Turn all breakers (main, 3-P and 1-P) to "OFF".
2) Turn the starter switch to the "STOP" position.
3) Add fuel to the fuel tank.
4) Set the idle control switch to "ECO" or "AUTO".
5) Turn the starter switch to the "START" position and crank the starter motor
for approximately 10 seconds.
6) After the engine starts, remove your hand from the starter switch.
7) Wait for air to be completely bled from the fuel pipes and engine speed to
stabilize (approx. 1-minute). (Engine speed is not stable until all air is bled
from the fuel pipes.)
<<<<
Note
>>>>
•
Do not switch the engine to high speed or apply any loads to it until all the air has
been bled from the fuel pipes (until speed is stable). Doing so can cause a
malfunction.
7-2
.
.
.
.
Stopping the Engine
1) Turn all breakers (main, 3-P and 1-P) to "OFF".
2) Set the idle control switch to "ECO" or "AUTO".
3) Allow the engine to cool down for approximately 5 minutes.
4) Set the starter switch to "STOP".
5) After the engine stops, turn the fuel lever to "CLOSE".
<<<<
Note
>>>>
•
Do not stop the engine while welding or using as an AC power source. Doing so
can cause a malfunction.
•
If the engine does not stop when the starter switch is set to "STOP" , turn the fuel
lever to "CLOSE" . The engine will stop a few minutes afterwards. If the engine
does not stop by starter switch operation, stop using the equipment and request
repair at the retail outlet where the equipment was purchased.
Main Breaker
Starter Switch
Preheat Lamp
Idle
Control
Switch
Fuel Lever
Close
Open
1-P
Breaker
3-P
Breaker
Summary of Contents for DGW400DM-C
Page 2: ......
Page 44: ...41 14 Engine Wiring Diagram...
Page 45: ...42 15 Generator Wiring Diagram...
Page 46: ...43...
Page 47: ...44...
Page 48: ...45 2013...