- 16 -
Caution: Burn
•
The engine, muffler and similar parts are extremely hot during operation
and immediately after stopping the equipment. Never touch hot parts.
Caution: Physical and Secondary Damage
•
Set the frequency in accordance with the devices using the equipment.
This equipment can operate at either 50Hz
or 60 Hz.
Set the frequency selector located inside the
side door to change the frequency in
accordance with the devices using the
equipment.
<<<<
Note
>>>>
•
The frequency lamp lights up on the side of
the corresponding set frequency.
5-10
.
.
.
.
Voltage Adjustment Dial
Use the dial for adjusting the output voltage of the AC power source when you
need to adjust the voltage.
The equipment is normally used with the dial set at the center position.
<<<<
Note
>>>>
•
The output current decreases as the
voltage increases. (Use within the rated
output range.)
•
Setting higher than the allowable
voltage of devices using the equipment
can result in the malfunction of such
devices.
5-11
.
.
.
.
Earth Leakage Circuit Breaker and Grounding
Warning: Electric Shock
•
Always be sure to repair the corresponding earth leakage location when
earth leakage circuit breakers operate.
Warning: Fire
•
Do not ground wiring of earth leakage circuit breakers of the equipment
to piping that passes through flammable material.
The equipment includes earth leakage circuit breakers (solidly grounded type) in
order to prevent electric shock. Immediately isolate the electrical circuit if earth
leakage occurs due to insulation failure in devices using the equipment or similar
reason.
Frequency
Selector
AC
Voltage
Adjustment
Dial
Increase
Decrease