25
8-7. Checking the Battery
CAUTION : EYE/SKIN INJURY
Wear rubber gloves and other protective wear to protect eyes, skin and
clothing from the battery fluid which contains diluted sulfuric acid. If the
battery fluid contacts eyes or skin, wash out immediately with a large amount
of water. Be sure to receive medical treatment, especially if the fluid contacts
the eyes.
CAUTION : EXPLOSION
Never use or recharge the battery if the fluid level is below the minimum
level.
Do not create sparks or bring flame near the battery as it generates
flammable gas.
Check the fluid level, and add distilled water when it is near the lower level until it
reaches the upper level.
Check the terminals for looseness and tighten if loose.
< NOTE >
It is necessary to recharge the battery when the specific gravity of the battery fluid is 1.23 or less.
Request the authorized distributor where the generator was purchased to recharge the battery.
Replacing the Battery
Remove the battery negative (-) cable. (Always be sure to remove the negative (-) side
first. )
Remove battery hold-down clamp.
Remove the battery positive (+) cable.
Remove the battery.
* Install the battery by performing the above procedures in the reverse order.
(First connect the positive (+) cable of the replaced battery. )
1
Upper Level
Lower Level
(-) Post
(
+
) Post
Hold-Down
Clamp
3
4
1
2
2
Summary of Contents for DGM60MK
Page 2: ......
Page 46: ...43 13 Generator Circuit Diagram...
Page 47: ...44 14 Engine Electrical Circuit Diagram...
Page 48: ...2011...