36
Replace the packing of the coolant drain plug with new packing each time the coolant is changed.
Packing part no.: 6C090-58961 (Kubota part no.)
After reinserting the coolant drain plug and shortly after starting the engine, be sure to always
check that there is no coolant leakage.
(8) Flushing Liquid in Spill Containment
Check
Daily
Set a container to collect liquid from the flushing port of the drain valve on the front of
this generator.
Remove the drain valve plug (R 1/2) and open the valve lever.
< NOTE >
When removing or attaching the plug, hold the drain valve fixed using a spanner or similar tool
and turn the plug.
If oil or other liquid is mixed in with the flushed liquid, this indicates that there is an oil leak. In such
case, check for the leak location.
The types of liquids that can accumulate in the spill containment include oil, fuel, coolant water
and battery fluid such that it is not possible to distinguish between rain water and other liquids.
Dispose of flushed liquids according to the related laws and regulations.
Close the valve lever after the liquid has been flushed, and apply sealant coating to the
plug or wrap it in seal tape.
3
1
Plug
Loosen
Tighten
Fixing
Drain Faucet
Plug(R1/2)
Drain Faucet Lever
Drain Faucet
Drain Faucet
Lever
Close
Open
2