37
(10) Spill Containment Cleaning/Inspection
WARNING : INJURY
Do not lift up the unit using tie downs. Use of such could result in the generator falling.
No persons should ever be under a lifted generator.
CAUTION : INJURY
Always be sure to use lifting hooks when lifting up the generator, and raise it
slowly at a completely vertical angle.
Personnel performing lifting work must wear protective gears such as helmets,
safety shoes and gloves.
Do not move the generator during operation.
Clean
Every 500 hours
Separate the spill containment from this generator to clean and inspect the spill containment.
Spill Containment Separate/
Reassemble
Turn the 3way fuel valve lever to the “B” side.
Remove the wiring connector.
Remove the fuel hoses (supply and return sides).
Remove the four spill containment fixing bolts (M12, 4 pieces).
< Note >
When removing the fuel hoses, hold the union joint fixed using a spanner or similar tool.
Prepare a container to receive the fuel remaining in the fuel piping that will flow out of the
removed fuel piping.
Lift the generator, separate the spill containment and set the generator on a flat surface.
After cleaning and inspecting the inside of the spill containment, reassemble the spill
container with this generator by performing the above procedures in the reverse order.
Reassemble the fuel piping and wiring connector to their original positions.
Turn the 3way fuel valve lever to the “A” side.
< Note >
After reassembling, bleed air from the fuel system.
(
Refer to section “
9-2. Procedures during Operation
”.)
After reassembling, check that there is no fuel leakage.
5
Drain Valve
Drain Valve
Lever
Close
Open
1
2
3
6
7
Drain Valve Lever
Drain
Plug(R1/2”)
4
8
Position B
Position A
Drain Plug
Loosen
Tighten
Fixing
Drain Valve