Shindaiwa DGK14F Owner'S And Operator'S Manual Download Page 1

 

 
 
 
 

 

 

 

 

 

 

OWNER

S AND OPERATOR

S MANUAL 

 

 

 

 

Vertical, Water-Cooled 4-Cycle Diesel Engine 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

DGK14F

 

X753-007  45  0 

X753801-230  0 

 

CAUTION

 

Do not operate the Generator, or any other appliance, before you have read and 
understood the instructions for use and keep near for ready use. 

 

California Proposition 65 

  WARNING 

Breathing diesel engine exhaust exposes you to chemicals known to the State of 
California to cause cancer and birth defects or other reproductive harm. 

  Always start and operate the engine in a well ventilated area. 

  If in an enclosed area, vent the exhaust to the outside. 

  Do not modify or tamper with the exhaust system. 

  Do not idle the engine except as necessary. 

For more information go to www.P65warnings.ca.gov/diesel. 

  WARNING 

Cancer and reproductive Harm- 
www.P65Warnings.ca.gov 

 

WARNING 

Batteries, battery posts, terminals and related accessories contain lead and lead 
compounds, and other chemicals known to the State of California to cause cancer 
and birth defects or other reproductive harm. WASH HANDS AFTER HANDLING. 

 

Summary of Contents for DGK14F

Page 1: ...irth defects or other reproductive harm Always start and operate the engine in a well ventilated area If in an enclosed area vent the exhaust to the outside Do not modify or tamper with the exhaust sy...

Page 2: ......

Page 3: ...ration Store this manual in a specified location where it will be secure and available for consulting at any time Order another copy from the authorized distributor where this generator was purchased...

Page 4: ...ures 16 6 2 Installation Procedures 17 7 Load Connections 18 7 1 Load Cable Selection 18 7 2 Connecting Load Cables 19 8 Pre Operation Inspection 20 8 1 Checking Engine Oil 20 8 2 Checking Coolant 21...

Page 5: ...tion Do not open the check door when the starter switch is in the AUTO or START position It will cause injury by rotating parts such as cooling fans and fan belt Always turn the starter switch to the...

Page 6: ...s repair the leaking location before operating Always be sure to wipe up any spilled fuel or oil Allow the generator to cool before covering with the protective cover Never allow flame to come close t...

Page 7: ...Securely fix the equipment with rope or similar item so that it cannot move when transporting by truck or other vehicle CAUTION PROPERTY DAMAGE Do not use the equipment for any improper applications I...

Page 8: ...840 Warnig Fire Part no X505 007650 Caution Burn Part no X505 007830 Warnig caution Part no X505 010910 Warnig Injury Part no X505 007550 Bonnet grounding terminal Part no M704 001400 Spill containmen...

Page 9: ...n mm 3 3 27 3 64 83 92 4 Continuous Rated Output hp 19 5 Rated Speed rpm 1800 Displacement cu in liters 91 5 1 499 Combustion System Indirect Injection Cooling Method Radiator Lubricating Method Force...

Page 10: ...midity 85 or less Altitude 984 ft 300 m or less 3 Applications Power source for submerged pumps and similar civil engineering equipment Power source for lighting and similar equipment Power source for...

Page 11: ...lternator Check Door Air Cleaner Coolant Sub Tank Engine Check Door External Fuel Inlet External Fuel Return Oil Drain Plug Coolant Drain Plug 3way Fuel Valve Radiator Shown with side plate removed Ac...

Page 12: ...t Lamp 13 Engine Monitor Glow Lamp 14 Fuel Meter Throttle Switch 15 Oil Pressure Water Temperature Speed Selector Switch Voltage Regulator 16 Display Selector Switch Starter Switch 17 Available Output...

Page 13: ...Containment for inspection procedures Refer to section 10 Inspection Maintenance 9 Flushing Liquid in Spill Containment for flushing procedures The generator is equipped with the following in order t...

Page 14: ...ault occurs during operation and the engine automatically stops depending on the fault type except for SPILL CONTAINMENT If the generator automatically stops set the starter switch to STOP and restart...

Page 15: ...sh out of the coolant sub tank Check the coolant sub tank coolant level after the generator cools and add coolant to the coolant sub tank if it is insufficient Refer to section 8 2 Checking Coolant If...

Page 16: ...ction Maintenance 9 Flushing Liquid in Spill Containment Note Although the fluids that can leak internally consist of oil fuel and coolant the spill containment does not have a function that can separ...

Page 17: ...uel Meter It shows the amount of fuel in the tank All lamps are lit when the amount reaches to the maximum level and FULL is lit decreases The lit lamp decreases as the amount of fuel in the tank reac...

Page 18: ...R SWITCH selector to STOP to activate this function Do not leave the ACCESSORY switch at ON position This is causing battery from drain out 3 Breaker This switch is for transmitting electrical power t...

Page 19: ...ternal tank fuel inlet return 2 If using an external fuel tank Connect hoses from the external fuel tank to the external fuel inlet and the external fuel return Change the lever of the 3way fuel valve...

Page 20: ...ings CAUTION FIRE Do not carry flammable items such as fuel gas and paint or items that are highly combustible near the generator as the muffler exhaust gas and other parts become extremely hot Operat...

Page 21: ...h locations 7 Load Connections 7 1 Load Cable Selection CAUTION PROPERTY DAMAGE Cable burnout could occur due to generated heat if the load current exceeds the allowable current of the cable The volta...

Page 22: ...generator output setting receptacle connection position and load power source are all matching Use proper tools when connecting a load to tighten properly Failure to sufficiently tightened will result...

Page 23: ...on remove the oil level gauge and wipe so that no oil remains and then re insert the dipstick fully Prior to starting the engine make sure to fill the engine oil through the oil filler until it reache...

Page 24: ...Fill with coolant through the filler neck until the radiator is full Re attach and tighten the radiator cap Attach the radiator plate Note Use GM SPEC 6277M or equivalent Use a 50 50 mix of Long Life...

Page 25: ...iquid in Spill Containment Check if there is a sufficient amount of fuel and add fuel if insufficient The fuel meter on the control panel will only display the fuel level for the internal fuel tank Be...

Page 26: ...with a large amount of water Be sure to receive medical treatment especially if the fluid contacts the eyes CAUTION EXPLOSION Never use or recharge the battery if the fluid level is below the minimum...

Page 27: ...load side that power will be turned on before operating the breaker Close all doors and lock them during operation Do not open the check door when the starter switch is in the AUTO or START position I...

Page 28: ...f a door is opened suddenly and is closed a finger might be sandwiched 1 Manual Start Turn off the main breaker on the operation panel of this machine Set the ACCESSORY switch to OFF and use the safet...

Page 29: ...this generator and request authorized distributor where the generator was purchased to repair the generator 2 Adjustment during Operation During load operation check the voltmeter and finely adjust v...

Page 30: ...RT position the standby current may drain the battery 2 Auto Start The engine stops when the REMOTE START terminal opens Set the STARTER SWITCH selector to STOP position and close the fuel levers if t...

Page 31: ...p High Water Temperature Activates due to high water temperature in the engine Default 239 F 115 2 Low Oil Pressure Activate due to low oil pressure in the engine Default 7 psi 0 49 100 kPa 3 Insuffic...

Page 32: ...is generator will result in poor engine operation or stoppage Turn the 3way fuel valve lever to the A side in order to prevent fuel from flowing out from the external tank fuel inlet return Turn the l...

Page 33: ...helmets safety shoes and gloves Always be sure to use lifting hooks when suspending the generator and raise it slowly at a completely vertical angle Perform periodic inspection and maintenance accordi...

Page 34: ...Engine Each parts Clean Tightening Engine oil Check Add Engine oil Replace 1st time at 50 hrs Oil filter Replace 1st time at 50 hrs Coolant Check Add Coolant Replace Radiator Flush or 2years Exhaust c...

Page 35: ...is attached open the oil drain valve and drain the engine oil After the oil has been drained close the oil drain valve and reinsert the oil drain plug with new packing a rubber seal is attached Add oi...

Page 36: ...ent Cleaning Replacement First Time clean 50 hours Thereafter clean Every 100 hours Replace once in 6 times cleaning or Every 1 year Remove the air cleaner clips and cleaner cap Remove the element Cle...

Page 37: ...al location Note When attaching the cup check that there is no foreign material adhering to the O ring After attaching open the fuel valve and be sure to always start the engine and check that there i...

Page 38: ...kage 7 Coolant Replacement Replace Every 1000 hours or 2 years Set a container to catch spilled coolant Remove the radiator plate Remove the radiator cap Remove the coolant drain plug and packing Afte...

Page 39: ...as purchased to replace the fan belt 9 Flushing Liquid in Spill Containment Check Daily Set a container to collect liquid from the flushing port of the drain valve on the front of this generator Remov...

Page 40: ...four spill containment fixing bolts M12 4 pieces Note When removing the fuel hoses hold the union joint fixed using a spanner or similar tool Prepare a container to receive the fuel remaining in the...

Page 41: ...accumulate and check that the spill containment has no internal leakage Remove the drain plug R1 to drain the water After the procedures have been completed apply sealant coating to the plug R1 or wr...

Page 42: ...ator if it has been modified or any parts have been removed Position the generator on a level stable surface so that it cannot slide or move in any manner Before starting operation always be sure to t...

Page 43: ...battery to the appropriate level and recharge approximately every month 2 Double Stacking Storage Procedures WARNING INJURY Always be sure to observe the following items when double stacking this gene...

Page 44: ...eriorated 3 Battery terminal is OFF or loosen 4 Battery terminal is corroded 5 Starter switch or relay is defective 6 Starter motor is defective 7 ECU Engine Controller is defective 1 Check battery fl...

Page 45: ...r 3 Ask our distributor to repair 4 Check Adjust fan belt 5 Check Add coolant 6 Clean radiator core Black smoke comes out from Muffler 1 Air filter element is clogged 2 Fuel injection nozzle is defect...

Page 46: ...Over load 4 AVR protective device operation 1 Ask our distributor to repair 2 Change to a device with an available capacity 3 Decrease the loads to meet the rated output 4 Replace AVR fuse Cannot tur...

Page 47: ...44 13 Generator Circuit Diagram...

Page 48: ...45 14 Engine Electrical Circuit Diagram...

Page 49: ......

Page 50: ...2019...