23
(2) Checking coolant in Sub Tank / Adding coolant
Check to see if the water/coolant level is between FULL and LOW line in the
Sub Tank.
Fill up to the FULL line, if the water/coolant level is low.
< Note >
Use soft water, such as tap water.
If the outside temperature is near freezing, use Long Life Coolant (LLC)(30% mixture
LLC is used, when shipped from factory).
Use same type of coolant with identical mixture ratio for the Sub Tank.
Mixture ratio of the coolant should be between 30 to 50%, depending on the ambient
temperature.
When replenishing LLC, be sure to use the same brand as the LLC left
in the
Radiator and Sub Tank.
Never use the mixed LLC by different brands or specifications.
Replace LLC every 2 years or 1000 hours.
Mixture ratio (for reference only) :
Ambient
temperature
-
15
℃
-
23
℃
-
35
℃
Mixture ratio
30%
40%
50%
(3) Coolant Volume
Unit: L
Total Coolant Volume (including Sub Tank)
17 (1.5)
The value of ( ) shows the Sub Tank volume.