13
5-4. Fuel Line Changeover Valve (3-way valve)
By switching the 3-way valve, you can use fuel from external fuel tank.
In this case, the built-in tank fuel cannot be used.
(1) Using fuel from built-in fuel tank
The lever for 3-way valve is set to
A
when the equipment is shipped.
Outer fuel inlet and return are
closed with plugs (PT1/2).
Use fuel as they are.
< Note >
After having used the outer fuel and removed piping, be sure to set the lever to A position and
fix the plugs.
(2) Using fuel from external fuel tank
Connect hoses from the external fuel tank to the external fuel intake and the external fuel return
ports, and set the lever for 3-way valve to
B
position.
You can now supply the fuel from
the external gas tank.
For detailed instructions, refer to
『
9-5.Connecting to External Fuel
Tank
』
CAUTION : Fire
Always stop the engine when performing any work on the fuel line.
Always wipe any drip of Diesel fuel or engine oil. Do not use this equipment,
when a leak is found. Repair the equipment before use.
Be sure to confirm that there is no leakage in the piping.
3-way valve
External Fuel Inlet (PT1/2)
External Fuel Return (PT1/2)
A side Lever Position
B side Lever Position
3-way valve
External Fuel Inlet
External Fuel Return