41
Eyebolt
Joint Pipe
Joint Pipe
Eyebolt
(6) Clean gauze filter in water separator
Clean
Every 500 hours
Loosen the lever and then loosen the air
extraction plug.
Turn the ring nut counter-clockwise to
remove the cup and the gauze filter after
the fuel inside does not come out from the
lever.
Wash the gauze filter in Diesel fuel and
reinstall the unit in the reverse order.
Tightening Torque
Ring Nut
15Nm{1.5kgfm}
Air Extraction Plug
10Nm{1.0kgfm}
< NOTE >
Clean the filter more frequently as gauze filter is clogged in shorter period when using the fuel
from the fuel drum than other fuel source.
Put a tray under the lever in order to catch spilled fuel when loosing the lever.
Extract the air in fuel line after gauze filter washing finishes.
(Refer to “9-2. Procedures during Operation”)
Ensure that there is no fuel leakage after reinstallation.
(7) Clean gauze filter in engine feed pump
Clean
Every 500 hours
Remove eyebolts.
Remove gauze filter in eyebolts.
Wash gauze filters in Diesel fuel and reinstall in
the reverse order.
Eyebolt tightening torque
44Nm{4.5kgfm}
1
2
3
AIR
EXTRACTION
PLUG
GAUZE FILTER
RING NUT
1
2
3