34
Execution PID setting screen
Initial Value : 1
Setting range :1 ~ 8
Step1 output1 PIDNo. setting screen
It have to be used both Out 1 and Out2.
Time signal 1 ON time setting screen
Initial value:
Setting range :00:00 ~300:00 (min:sec Hour:min)
0.0 ~3000.0 (hour)
About time signal
ON time is the time that will be ON after step bigan.
Time signal setting screen is displayed at EV or DO I is allotted to time signal.
Time signal setting has to be OFF when time setting is longer than step time.
When only ON time setting is set, it keep status ON until other step will be OFF.
When hold function is activated at program function, time signal Time also stops
temporarily.
Time signal ON statue have to be finish compulsorily in pattern end.