12
5-1.
Explanation of each functions
①Display of measured value (PV) (red)
Measured value (PV) and type of setting is displayed on each setting screen.
②Display of target value (SV) (green)
Target value and set value are displayed on each setting screen.
③Pattern No, Display (Green) (PID No, on MAC6)
Execution pattern No, (1-8) is displayed at program operation.
Execution SV No, is displayed at FIX operation.
④Step No, display (Yellow) (SV No, on MAC6)
Execution step No, is displayed (1- 96) at program operation.
Execution PID No, is displayed at FIX operation.
⑤Status LED Display
RUN : Light on at RUN Operation, Blinking at Manual operation.
AT : If AT is chosen in ON or external control input (DI), blinks during AT execution. Lights up when
AT is on standby, and Off with AT automatic termination or release.
PRG : On at the time of program control's standby or flat part control. Off at the time of FIX control
selection.
OUT1 : At the time of a contact or a voltage pulse output, On with ON and Off with OFF. At the time
Current Output or a Voltage Output, OFF with 0% power output, and ON with 100% power. And blinks
at intermediate ratio.
OUT2 : Same as Output1
EV1:ON at the allotted event output turns to ON
EV2~EV4:Same as EV 1
DO1:ON at the allotted event (DO) output turns to ON
DO2~DO6:Same as DO1
GUA(Guarantee soak):ON at GUA function execution.
During program operation, the SV value on program step proceed to flat step from ramp step, the PV
value some time delay from the SV value and the flat step become shorter than the step. This
function avoid and assuring the time of flat step.
HLD:ON at Hold function execution
(UP step) :ON at UP step execution
(FLAT step) :ON at FLAT step execution
(DOWN step) :ON at DOWN step execution
⑥Bar graph display (20 Dot LED)
Bar graph displayed Output value, Valve position, progress of the program operation by 0% to 100%.
(5% per dot)