70
4. Parameter description
Parameter
Parameter
Factory setting
Setting range
Remarks
50Hz
When P.189=1
39
60Hz
1~400Hz
When P.189=0
Note: 1. In
‘
external mode
’
,
‘
combined mode 2
’
or
‘
combined mode 4
’
, if AU is
‘
on
’
, the target frequency of the
inverter is set by the input signal across terminal 4-5.
2. In
‘
external mode
’
,
‘
combined mode 2
’
or
‘
combined mode 4
’
, if AU and one of RH, RM, RL and REX
are both valid at the same time, the multi-speed has higher priority.
3. RL, RM, RH, REX and AU referred in this paragraph are function names of
‘
multi-function control
terminal
’
. For the corresponding function selection and features, please refer to P.80~P.84
、
P.86
、
P.126~P.128. For wiring, please refer to Section 2-5.
4.20
Multi-function output (P.40, P.85, P.120, P.129, P.130)
P.40
“
Multi-function SU output
terminal pattern
”
P.85
“
Function selection for
multi-function relay
”
P.129
“
Multi-function RUN output
terminal pattern
”
P.130
“
Multi-function FU output
terminal pattern
”
P.120
“
The output signal delay time
”