80
4. Parameter description
Parameter
Note: 1. The frequency can be varied by RH (acceleration) and RM (deceleration) between 0 and the maximum
frequency. The upper limit of the setting frequency is the maximum frequency, showen as follows:
2. When the acceleration or deceleration signal is
‘
on
’
, the output frequency acceletaion/deceleration times
are determined by P.7 (first acceleration time) and P.8 (first deceleration time) (When RT is
‘
off
’
).
3. When P.44
≠
99999 (secone acceleration time) and P.45
≠
99999 (secone deceleration time),the
acceleration/deceleration times are due to P.44, P.45.
4. When the start signal (STF/STR) is
‘
off
’
, if RH (acceleration)/RM (deceleration) is
‘
on
’
, the target
frequency will also change.
5. When the start signal(STF/STR) becomes
‘
off
’
from
‘
on
’
, or changing the frequency continually through
RH/RM, please make the frequency setting storage function invalid (P.61=2,3).
6. If the frequency setting storage function is valid (P.61=1), the life of the EEPROM will be shorten because
of frequent write frequency into the EEPROM.
7. Signals RH, RM and RL are determined by P.80~P.84
、
P.86
、
P.126~P.128. If the functions of the terminals
are changed, other functions are likely to be affected. Please make sure the functions of the terminals
before changing their functions.
PDF created with pdfFactory trial version