17
- TIG lift.
- welding MMA (covered electrode) of the pulse.
t
AND
freq
Duty
- welding MMA (coated electrode).
I - selection button diameter of the wire electrode
The only active during MIG / MAG modes
.
and
.
Used to select the diameter of the wire electrode. Selecting the appropriate mode is confirmed by lighting of the LED.
J - Button Load Settings
Button is used for loading sets of parameters previously saved in the device memory. After pressing the button on the display shows a flashing number
and the LOAD parameter set to be loaded. Changes set number can be made by turning the knob (P). After pressing the knob (P) on the display
appears loaddata will be loaded and the selected set of parameters. To exit load settings and move to adjust the parameters, press the button (L).
K - saving the settings button
This button is used to store in the memory currently set parameters. You can save 35 sets of parameters. After pressing the button on the display
shows SAVE and flashing a set number of parameters, which will be saved under the current parameters. Changes set number can be made by
turning the knob (P). After pressing the knob (P) in the display appears SaveData and actual parameters are stored in memory.
P-p
cur