ShenZhen YH Innovative Technology, Inc.
70
70
70
70
Whole
Whole
Whole
Whole set
set
set
set ZX-1060
ZX-1060
ZX-1060
ZX-1060 SHERIFF
SHERIFF
SHERIFF
SHERIFF
1.
Trinket of two-way contact with LCD-display............................................................................................ 1piece
2.
Supplementary trinket of remote control..................................................................................................... 1piece
3.
Central module.............................................................................................................................................1piece
4.
Antenna module with LED indicator........................................................................................................... 1piece
5.
Two areas of sensor of hit............................................................................................................................ 1piece
6.
Service button “Valet”................................................................................................................................. 1piece
7.
Switch of start of engine “AST”.................................................................................................................. 1piece
8.
Button of bonnet (carrier)............................................................................................................................ 1piece
9.
Set of wires.................................................................................................................................................. 1piece
10. Manual of user and specification by installation..........................................................................................1piece
﹡
Anti-Hijack active transponder to whole set of system do not enter and it is obtained separately.
﹡﹡
Supplementary switch of central lock to whole set of system do not enter and it is obtained separately.
Basic
Basic
Basic
Basic technical
technical
technical
technical characteristic
characteristic
characteristic
characteristic
Voltage of delivery................................................................................................................................... 9-15V
Current of utilization in condition of protection....................................................................................... 20 milliampere
Maximal current of loading, commuting by outputs:
Siren......................................................................................................................................................... 2A
Light signal device (in condition of pulse control over light)................................................................... 15A
Light signal device (in condition of constant control over light).............................................................. 5A
Light signal device (in condition of pulse commutation)......................................................................... 15A
Chain of relay of blockage ARM (-)......................................................................................................... 0.5A
Chain of relay of blockage ARM (-)......................................................................................................... 0.5A
Doors locks............................................................................................................................................... 15A
Programmable channels:
CH2 (in condition of pulse commutation)................................................................................................ 10A (25A)
CH3.......................................................................................................................................................... 0.5A
CH4.......................................................................................................................................................... 0.5A
CH5 (in condition of pulse commutation)................................................................................................ 10A (25A)
CH6.......................................................................................................................................................... 0.5A
Built-in relay of starting engine................................................................................................................2x40A, 2x25A
Working scope of temperatures................................................................................................................ from -40
℃
to +85
℃
Radius of action of trinkets (at absent radio disturbing):
Six buttons trinket of two-way contact..................................................................................................... until 1000m
Five buttons.............................................................................................................................................. until 350m
Distance of transference of signal of emergency call............................................................................... until 2000m
Kind of code of trinket............................................................................................................................. dynamic
Number of possible combinations............................................................................................................ 2x10
23
Working frequency................................................................................................................................... 433.92MHZ