If the function is turned on, SF9 system will check the voltage of charging batteries in voltage of all cycle of
working engine under control over automatic start. The engine will be stopped immediately, if the voltage of
charging will exceed permissible limit in 16.5 V or disappear during the work of the engine (decrease below 11.5
V). Corresponding error will be recorded to memory of errors of automatic start.
Switch
Switch
Switch
Switch of
of
of
of automatic
automatic
automatic
automatic start
start
start
start “
“
“
“AST
AST
AST
AST”
”
”
”
The switch of automatic start “AST” is preassigned for emergency disconnection of the engine, which working
under the control by the system ZX-1060, temporary inhibition of the auto run, also for accomplishment function
by reprogrammable conditions of working auto run.
“AST” in condition “ON” – start is permitted.
“AST” in condition “OFF” – start is banned (“stop” the engine).
Remark
Remark
Remark
Remark
Line of emergency switch “AST” is incorporated physically with line of parking brake.
Before the control over
the program of function of auto run ascertain that parking brake is activated.
Condition
Condition
Condition
Condition of
of
of
of turbo
turbo
turbo
turbo timer/short
timer/short
timer/short
timer/short stops
stops
stops
stops (Pit-Stop)
(Pit-Stop)
(Pit-Stop)
(Pit-Stop)
The condition of turbo timer maintains working engine after turning of ignition off by the key (SF2 is turned on),
providing safe stop of turbo engine, also the possibility of short stop without turning of engine off (Pit-Stop).
Attention!
Attention!
Attention!
Attention!
Turbo timer ceases the work (is turned off) automatically until the expiration of installed time in the event of
emergency or spontaneous turning of engine off divesting delivery of side loading.
Turning on/turning off of
ignition without start of the engine do not turn on the turbo timer.
The engine works.
Turning of ignition off turn on the timer of delay during installed to SF2, contacts with the
relay of ignition IGN1 of system of auto run are remained by closed, IGN2, IGN3 are closed, providing the work of
the engine at any condition of the system.
At setting of the system to security, at line of blockage ARM, ARM is
remained in condition “Be turned off” until expiration of time of working timer of delay.
After that SF2 time of line “ARM”, “ARM” are activated to condition “Protection”, the line IGN1 of system of
remote start of the engine transfers to inactive condition (contacts with relay are opened, the engine will be stopped).
It is possible for emergency interruption of working turbo timer by means of trinket-transmitter at any time.
Reset
Reset
Reset
Reset of
of
of
of active
active
active
active condition
condition
condition
condition of
of
of
of turbo
turbo
turbo
turbo timer
timer
timer
timer with
with
with
with the
the
the
the help
help
help
help of
of
of
of transmitter
transmitter
transmitter
transmitter
�
Take out the key from the lock of ignition of the car.
�
Afterwards during 2 seconds twice press the button of trinket-transmitter (see picture 1): CH2 for momentary
disconnection TT or TT+timer of countdown in condition of manual box, iterative double pressing the button
6
– for disconnection TT in condition of manual box, button 6
– for momentary disconnection TT in