MX-M503N MX-FXX2 12 – 2
3)
Remove the two screws from the control PWB unit.
4)
Pull out the control PWB unit.
D. Attach the FAX memory.
E. Attach the interface cable.
1)
Connect the interface cable to the control PWB unit.
[Note] Check that the connector is not obliquely inserted.
2)
Push the interface cable into the recessed portion of the sheet
metal on the control PWB unit.
3)
Fix a snap band with the bundled M3 screw.
F. Attach the control PWB and the right cabinet
rear.
1)
Push the control PWB unit into the main unit and secure it with
the two screws.
2)
Cut out the cut-out portion of the right cabinet rear.
3)
Fit the interface cable into the opening that has been cut.
4)
Attach the right cabinet rear cover to the main unit.
At this time, check that the four hooks are properly fitted to the
main unit.
5)
Secure the right cabinet rear with the screw.
6)
Attach the ozone filter cover to the main unit.
PROG1
PROG2
FAX IMG EXT
PCL/BARCODE
PS KANJI
1
2
3
2
Hook 1 Hook 2
Hook 3
Hook 4
3
5
4