MX-M503N MX-FN10 7 – 5
2)
Connect the finisher connector with the connector of the main
unit, and tighten the screw.
G. Staple position label attachment
1)
Attach the label to the position indicated in the figure.
[For scanner] (package part No. 10)
[For DSPF/RSPF] (package part No. 11)
H. Turn on the power of the main unit
1)
Insert the power plug of the main unit into the power outlet.
2)
Open the front cabinet.
Turn ON the power switch in the front cabinet of the main unit.
3)
Turn ON the power switch on the operation panel.
Label attachment
reference
* Corner of the
"upper cabinet rear"
Corner R end fitting
Corner R end fitting
1mm
1mm
1mm
1mm
DSPF
RSPF
ON