MX-FR14U/FR14/FR15U/FR15/FR24U 22 – 1
: '10/Jun/18
1
Service Manual
[22] MX-FR14U/FR14/FR15U/FR15/
FR24U
* MX-FR14U/FR14
For model MX-M283N/M363N/M453N/M503N
For model MX-M363U/M453U/M503U with HDD
* MX-FR15U/FR15
For model MX-M363U/M453U/M503U without HDD
* MX-FR24U
For model MX-M282N/M362N/M452N/M502N
1. Unpacking
A. Check the packed items
1)
Check that all the items are included in the package.
2. Installation
<Note before installation>
• To enable the data security function, the product key must be
acquired. (For the method of acquiring the product key, contact
the dealer.)
• Before installing the data security kit, be sure to perform backup
of data stored in the memory (including HDD) of the main unit.
When the data security kit is installed, all the job data stored in
the memory (including HDD) of the main unit will be lost.
• If the LINE indicator or the DATA indicator for the printer and
image transmission on the operation panel is lit or blinking, data
that has not been processed remains in the memory of the main
unit (including HDD). Output or transmit all the data to clear the
data remaining in the main unit and then start installation. (Check
to insure that neither the LINE indicator nor the DATA indicator
on the operation panel does light up or blink.)
A. Turn off the power switches of the main unit.
1)
Turn the power switch located on the operation panel to the
"OFF" position.
2)
After checking that the operation panel has gone out, open the
front cabinet and turn the main power switch to the "OFF" posi-
tion.
3)
Remove the power plug of the main unit from the outlet.
B. Pull out the control PWB.
•
If cables are connected to the control PWB unit, remove all
cables.
1)
Push the location indicated in the illustration to unlock, and
remove the ozone filter cover from the right cabinet rear.
2)
Remove the screw from the right cabinet rear.
3)
Remove the right cabinet rear.
4)
Remove the two screws from the control PWB unit.
•
If the fax box unit is installed, carry out steps 5), 6), and
7) additionally.
5)
Pull out the control PWB unit and remove the snap band.
6)
Remove the interface cable from the frame.
7)
Remove the connector.
8)
Pull out and remove the control PWB unit.
No.
Packed part names
Quantity
1
MFP_PRG1 ROM
1
2
MFP_PRG2 ROM
1
3
Operation manual
1
1
1
1
2
3
MFP
_PRG
1
MFP_PRG2
OFF
3
2
4
4
5
8
6
7
5