2. Installation
<Note before installation>
* Before starting installation, check to insure that the data lamp on
the operation panel does not light up or blink.
A. Turn off the power of the main unit
1)
Turn OFF the power switch on the operation panel.
2)
Open the front cabinet.
Turn OFF the power switch in the front cabinet of the main unit.
3)
Disconnect the power plug of the main unit from the power out-
let.
B. Removal of the paper holding plate unit
1)
Disengage the pawl, and remove the paper holding plate and
the paper holding plate holder together as a unit.
* Be careful to remove both of the paper holding plate (which
is easily removed alone) and the paper holding plate holder.
C. Installation of the inner finisher
1)
Open the front cover.
2)
Remove two screws, and remove the front cabinet upper.
3)
Disengage two pawls, and remove the paper exit tray cover.
4)
Remove four screws, and remove the paper exit tray.
* When removing the paper exit tray, there is no need to
remove the screws in the section (A).