MX-M264U SIMULATION 6 – 41
43-10
Purpose
Setting
Function (Purpose)
Used to set the postcard feed cycle
Section
Operation/Procedure
1)
Enter the set value with 10-key.
2)
Press [OK] key. (The set value is saved.)
43-20
Purpose
Function (Purpose)
Used to perform the low-temperature, low-
humidity (L/L) environment correction for
the fusing temperature setting of each
paper (SIM43-01).
Section
Operation/Procedure
1)
Select an item to be set with the scroll key.
2)
Enter the set value with 10-key.
3)
Press [OK] key. (The set value is saved.)
* WARMUP END TIME LL: 1 count = 1s change
Other correction values:
1 count = 1
C change
* Items C/D: Correction of "–5" is made for item C and Item D in the case of B5 size
Item
Display
Content
Setting
range
Default
value
A
POSTCARD CYCLE
Postcard feed cycle
1 - 99
50
Item
Display
Content
Setting
range
Default
value
A
HL_UM READY LL
Correction value for TH_UM set value in ready standby under LL environment
1 - 99
55
B
HL_US READY LL
Correction value for TH_US set value in ready standby under LL environment
1 - 99
55
C
HL_UM PLAIN BW LL
Correction value for black and white plain paper TH_UM set value under LL environment
1 - 99
55
D
HL_US PLAIN BW LL
Correction value for black and white plain paper TH_US set value under LL environment
1 - 99
55
E
WARMUP FUMON HL_US T LL
Correction value for fusing motor previous rotation start TH_UM set value under LL environment
1 - 99
50
F
WARMUP FUMOFF LL
Fusing motor prior rotation completion time under LL environment
1 - 99
50
G
WARMUP END TIME LL
Correction value for warm-up complete time under LL environment
1 - 99
50
H
HL_UM HEAVY LL
Correction value for heavy paper TH_UM set value under LL environment
1 - 99
55
I
HL_US HEAVY LL
Correction value for heavy paper TH_US set value under LL environment
1 - 99
55
J
HL_UM OHP LL
Correction value for OHP-TH_UM set value under LL environment
1 - 99
55
K
HL_US OHP LL
Correction value for OHP-TH_US set value under LL environment
1 - 99
55
L
HL_UM E-STAR LL
Correction value for preheating TH_UM set value under LL environment
1 - 99
55
M
HL_US E-STAR LL
Correction value for preheating TH_US set value under LL environment
1 - 99
55
N
HL_UM PRE-JOB LL
Correction value for the set value of TH_UM when restoring from preheating under LL
environment
1 - 99
50
O
HL_UM WARMUP_120L LL
Correction value for TH_UM set value in Warm-Up at 120
C or below under LL environment
1 - 99
55
P
HL_US WARMUP_120L LL
Correction value for TH_US set value in Warm-Up at 120
C or below under LL environment
1 - 99
55
Q
LO_WARMUP_TIME_LL
Correction value for O, P applying time (timer from Ready complete) under LL environment
1 - 99
50
R
HL_UM WARMUP_120H LL
Correction value for TH_UM set value in Warm-Up at 120
C or above under LL environment
1 - 99
55
S
HL_US WARMUP_120H LL
Correction value for TH_US set value in Warm-Up at 120
C or above under LL environment
1 - 99
55
T
HI_WU_TIME_LL
Correction value for R, S applying time (timer from Ready complete) under LL environment
1 - 99
50
U
HI_WU_FM_ON_TMP_LL
Correction value for FM prior rotation start TH_UM in Warm-Up at alpha
C or above under LL
environment
1 - 99
50
V
HI_WU_END_TIME_LL
Correction value for Warm-Up completion time in Warm-Up at alpha
C or above under LL
environment
1 - 99
50
W
HI_WU_JOB_SET_TMP_LL
Correction value for Job enable TH_UM temperature (1) when Warm-Up at alpha
C or above
under LL environment
1 - 99
50
X
HI_WARMUP_BORDER_LL
Correction value for the threshold value alpha applying SIM43-1-U - W under LL environment
1 - 99
50
Y
LO_WU_JOB_SET_TMP_LL
Correction value for Job enable TH_UM temperature (1) when Warm-Up at alpha
C or below
under LL environment
1 - 99
50
Z
JOBEND_FUMON_TIME LL
Correction value for the after rotation time when completing a job under LL environment
1 - 99
50
AA
HI_WU_JOB_SET_TMP 2 LL
Correction value for Job enable TH_UM temperature (2) when Warm-Up at alpha
C or above
under LL environment
1 - 99
50
AB
LO_WU_JOB_SET_TMP 2 LL
Correction value for Job enable TH_UM temperature (2) when Warm-Up at alpha
C or below
under LL environment
1 - 99
50