MX-M264U SIMULATION 6 – 38
Code descriptions
List of destination groups
P
HL_US WARMUP_120L
TH_US set value when Warm-Up
at 120
C or below
70 - 220
130
180
180
180
190
190
190
190
Q
LO_WARMUP_TIME
O, P applying time (Timer from
completion of Ready)
0 - 255
0
0
0
0
0
0
0
0
R
HL_UM WARMUP_120H
TH_LM set value when Warm-Up
at 120
C or above
70 - 220
130
180
180
180
190
190
190
190
S
HL_US WARMUP_120H
TH_US set value when Warm-Up
at 120
C or above
70 - 220
130
180
180
180
190
190
190
190
T
HI_WARMUP_TIME
R, S applying time (Timer from
completion of Ready)
0 - 255
0
0
0
0
0
0
0
0
U
HI_WU_FM_ON_TMP
FM prior rotation start TH_US
when Warm-Up at alpha
C or
above
0 - 220
0
0
0
0
0
0
0
0
V
HI_WU_END_TIME
Warm-Up completion time when
Warm-Up at alpha
C or above
0 - 60
18
18
18
18
18
18
18
18
W
HI_WU_JOB_SET_TMP 1
Job enable TH_UM temperature 1
when Warm-Up at alpha
C or
above
30 - 220
130
180
180
180
190
190
190
190
X
HI_WARMUP_BORDER
Threshold value alpha to which U -
W is applied
1 - 119
60
60
60
60
60
60
60
60
Y
LO_WU_JOB_SET_TMP 1
Job enable TH_UM temperature 1
when Warm-Up at alpha
C or
below
70 - 220
130
180
180
180
190
190
190
190
Z
JOBEND_FUMON_TIME
After rotating time when a job is
completed
0 - 60
0
0
0
0
0
0
0
0
AA
HI_WU_JOB_SET_TMP 2
Job enable TH_UM temperature 2
when Warm-Up at alpha
C or
above
70 - 220
130
180
180
180
190
190
190
190
AB
LO_WU_JOB_SET_TMP 2
Job enable TH_UM temperature 2
when Warm-Up at alpha
C or
below
70 - 220
130
180
180
180
190
190
190
190
Item/Display
Content
Setting
range
Default value
Group A
Group B
Group C
Group D
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
TH_UM
Fusing thermistor main (Front surface of paper)
HL_UM
Heater lamp main (Heat roller for front surface of paper)
TH_US
Fusing thermistor sub (Front surface of paper)
HL_US
Heater lamp sub (Heat roller for front surface of paper)
SW-A
Setting value when plain paper is selected in the system setting/device setting/fusing control setting.
SW-B
Set value when heavy paper is selected in the system setting/device setting/fusing control setting.
The set value displayed in this simulation differs depending on plain paper or heavy paper which is selected in the system setting/device setting/fusing
control setting.
(Example) When plain paper is selected in the system setting/device setting/fusing control setting, the value of SW-A is displayed.
Group
Destination
Group A
JAPAN
–
–
–
–
Group B
U. S. A
CANADA
INCH
–
–
Group C
AB_B
EUROPE
U. K
AUS.
AB_A
Group D
CHINA
–
–
–
–