MX-M264U SIMULATION 6 – 29
26-78
Purpose
Setting
Function (Purpose)
Used to set the password of the remote
operation panel.
Section
Operation/Procedure
1)
Enter a password with 10-key. (5 - 8 digits)
The entered password is displayed on the column of "NEW".
In order to correct the entered password, press the [clear] key
to delete the entered value one digit by one digit.
2)
Press [SET] key.
26-79
Purpose
Setting
Function (Purpose)
Used to set YES/NO of the pop-up display
of user data delete result.
Section
Operation/Procedure
1)
Enter the set value with 10-key.
The value for the display operation specification after comple-
tion of user data delete is set.
2)
Press [OK] key.
27
27-1
Purpose
Setting
Function (Purpose)
Used to set non-detection of communica-
tion error (U7-00) with RIC. (FSS function)
Section
Operation/Procedure
1)
Enter the set value with 10-key.
2)
Press [OK] key.
The set value in step 1) is saved.
27-2
Purpose
Setting
Function (Purpose)
Used to set the sender's registration num-
ber and the HOST server telephone num-
ber. (FSS function)
Section
Operation/Procedure
1)
Select an item to be set with touch panel.
[USER FAX NO] [SERVA TEL NO]
2)
Enter the set value with 10-key.
3)
Press [SET] key.
The set value in step 2) is saved.
Item/Display
Content
Setting range
Default
value
A
DISP SET
User data delete result
pop-up display ON
YES
1
0 (NO)
User data delete result
pop-up display OFF
NO
0
0
Not detection
1
Detection
USER FAX_NO.
Sender registration number (Max. 16 digits)
SERVA TEL_NO.
Host server telephone number (Max. 16 digits)
• If the connection process is not completed
normally when registering the FSS, calling to the
HOST may be continuously made every time
when the power is turned ON (from OFF) or
rebooted.
In this case, enter "********" to inhibit calling to the
HOST.