MX-M264U SIMULATION 6 – 35
41-3
Purpose
Operation test/check
Function (Purpose)
Used to check the operations of the docu-
ment size sensor and the control circuit.
Section
Operation/Procedure
The detection output level (A/D value) of OCSW and the document
sensor (PD1 - PD7) is displayed in real time.
The light receiving range of PD1 - PD7 is 1 - 255. (Default: 128)
43
43-1
Purpose
Setting
Function (Purpose)
Used to set the fusing temperature in each
mode.
Section
Operation/Procedure
1)
Select an item to be set with scroll keys.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2) is saved.
26cpm machine
Item/Display
Content
Detection level range
OCSW
Original cover SW
0-1 ("1" to Close)
PD1
Document detection 1
0 - 255
PD2
Document detection 2
0 - 255
PD3
Document detection 3
0 - 255
PD4
Document detection 4
0 - 255
PD5
Document detection 5
0 - 255
PD6
Document detection 6
0 - 255
PD7
Document detection 7
0 - 255
Item/Display
Content
Setting
range
Default value
Group A
Group B
Group C
Group D
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
A
HL_UM READY
Ready standby TH_UM set value
70 - 220
175
175
175
175
180
180
180
180
B
HL_US READY
Ready standby TH_US set value
70 - 220
170
170
170
170
175
175
175
175
C
HL_UM PLAIN PAPER BW
Black-White plain paper TH_UM
set value
70 - 220
175
180
175
180
185
190
185
190
D
HL_US PLAIN PAPER BW
Black-White plain paper TH_US
set value
70 - 220
175
180
175
180
185
190
185
190
E
WARMUP FUMON HL_UM T
Fusing motor pre-rotation start
TH_US set value
0 - 200
0
0
0
0
0
0
0
0
F
WARMUP FUMOFF HL_UM T
Fusing motor previous rotation
complete time
0 - 60
0
0
0
0
0
0
0
0
G
WARMUP END TIME
Warm-up complete time
0 - 20
18
18
18
18
18
18
18
18
H
HL_UM HEAVY PAPER
Heavy paper TH_UM set value
70 - 220
190
190
190
190
I
HL_US HEAVY PAPER
Heavy paper TH_US set value
70 - 220
190
190
190
190
J
HL_UM OHP PAPER
OHP-TH_UM set value
70 - 220
175
175
185
185
K
HL_US OHP PAPER
OHP-TH_US set value
70 - 220
175
175
185
185
L
HL_UM E-STAR
Preheating TH_UM set value
70 - 220
95
95
95
95
95
95
95
95
M
HL_US E-STAR
Preheating TH_US set value
70 - 220
95
95
95
95
95
95
95
95
N
HL_UM PRE-JOB
TH_UM set value when recovery
from Warm-Up
70 - 220
130
175
175
175
175
175
175
175
O
HL_UM WARMUP_120L
TH_UM set value when Warm-Up
at 120
C or below
70 - 220
130
175
175
175
175
175
175
175
P
HL_US WARMUP_120L
TH_US set value when Warm-Up
at 120
C or below
70 - 220
130
170
170
170
170
170
170
170
Q
LO_WARMUP_TIME
O, P applying time (Timer from
completion of Ready)
0 - 255
0
0
0
0
0
0
0
0
R
HL_UM WARMUP_120H
TH_LM set value when Warm-Up
at 120
C or above
70 - 220
130
175
175
175
175
175
175
175
S
HL_US WARMUP_120H
TH_US set value when Warm-Up
at 120
C or above
70 - 220
130
170
170
170
170
170
170
170