MX-M264U SIMULATION 6 – 30
27-4
Purpose
Setting
Function (Purpose)
Used to set the initial call and toner order
auto send. (FSS function)
Section
Operation/Procedure
1)
Select an item to be set with scroll keys.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2) is saved.
27-5
Purpose
Setting
Function (Purpose)
Used to set the machine tag No. (This func-
tion allows the host computer to check the
machine tag No.) (FSS function)
Section
Communication (RIC/MODEM)
Operation/Procedure
1)
Enter the password (max. 8 digits) with 10-key.
The entered password is displayed on the column of "NEW”.
In order to correct the entered password, press the [clear] key
to delete the entered value one digit by one digit.
2)
Press [SET] key.
27-6
Purpose
Setting
Function (Purpose)
Used to set of the manual service call.
(FSS function)
Section
Operation/Procedure
1)
Enter the set value with 10-key.
2)
Press [OK] key.
The set value in step 1) is saved.
Item/Display
Content
Setting
range
Default
value
Remarks
A
FSS MODE
NEB1
Set the FSS MODE
Exclusive for send in NE-B mode
0 - 3
0
1
NEB2
Send/Receive in NE-B mode
1
NFB1
Exclusive for send in NE-F mode
2
For convenience
stores
NFB2
Send/Receive in NE-F mode
3
For convenience
stores
B
RETRY_BUSY
Resend number setting when busy
0 - 15
2
0: No retry
C
TIMER(MINUTE)_BUSY
Resend timer setting (minute) when busy
1 - 15
3
D
RETRY_ERROR
Resend number setting when error
0 - 15
1
0: No retry
E
TIMER(MINUTE)_ERROR
Resend timer setting (minute) when error
1 - 15
1
F
FAX RETRY
Resend number setting when FAX initial connection
0 - 15
2
Unit: Number of times
G
TONER ORDER
TIMING(K)
EMPTY
Toner order auto send
timing setting (K)
Empty
0 - 11
0
6
NEAR_END
Near end
1
0.05
0.05
2
0.1
0.1
3
0.15
0.15
4
0.2
0.2
5
0.25
0.25
6
0.3
0.3
7
0.35
0.35
8
0.4
0.4
9
0.45
0.45
10
0.5
0.5
11
H
TEMP HISTORY CYCLE
Frequency of acquiring the temperature and humidity history
1 - 1440
60
Unit: min.
I
LOG OUTPUT CAPACITY(PCU)
Log output capacity
0 - 50
30
Unit: [KB]
0
Allow (Default)
1
Inhibit