13.2.2.16 SSP Clock Prescaler Register (SSPPRE)
The value in this register is used as a divisor for the Source Clock to derive the SSP clock
(SSPCLK) frequency. The SSP clock source (System Clock Oscillator, or HCLK) is
selected with the PCLKSEL1:SSP bit (see Section 13.2.2.13). Table 13-39 shows the
valid combinations for SSPDIV and the resulting SSP clock frequency. Following reset, the
prescaler is programmed to pass the clock through without division. All other SSPDIV val-
ues are invalid.
Table 13-37. SSPPRE Register
BIT
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
FIELD
///
RESET
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
RW
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
BIT
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
FIELD
///
SSPDIV
RESET
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
RW
RO
RO
RO
RO
RO
RO
RO
RO
RW
RW
RW
RW
RW
RW
RW
RW
ADDR
0xFF 0x44
Table 13-38. SSPPRE Fields
BITS
NAME
DESCRIPTION
31:8
///
Reserved
Reading returns 0. Write the reset value.
7:0
SSPDIV
SSP Divisor
Program with the clock source divisor for the SSP Clock
prescaler (see Table 13-39).
Table 13-39. SSPPRE Register Values
SSPDIV
DIVISOR
ƒ(SSP)
0b00000000 (default)
1
ƒ(clock source)
0b00000001
2
ƒ(clock source)/2
0b00000010
4
ƒ(clock source)/4
0b00000100
8
ƒ(clock source)/8
0b00001000
16
ƒ(clock source)/16
0b00010000
32
ƒ(clock source)/32
0b00100000
64
ƒ(clock source)/64
0b01000000
128
ƒ(clock source)/128
0b10000000
256
ƒ(clock source)/256