AR-M256/M257/M258/M316/M317/M318/5625/5631 SIMULATION 8 - 3
3. Simulation code list
Code
Function
Main
Sub
1
1
Used to check the operation of the scanner unit
and its control circuit.
2
Used to check the operation of sensor and detector
in the scanning (read) section and the related circuit.
2
1
Used to check the operation of the RSPF unit and
the related circuit.
2
Used to check the operation of sensors and detectors
in the RSPF unit and the related circuit.
3
Used to check the operation of the loads in the
RSPF unit and the control circuits.
3
2
Used to check the operation of sensor and detector
in the finisher and the related circuit.
3
Used to check the operation of the load in the
finisher and the control circuit.
6
Used to adjust the alignment position (side
regulation plate, rear edge regulation plate) for
each paper size.
Shifts to the specified paper size position.
7
Used to adjust the offset tray operations.
10
Used to make each adjustment of the saddle finisher.
11
Used to check the shifter operation.
Reciprocating operations are continuously
performed or the home position is checked.
(The shifter is shifted to the home position or
moved in one way by the specified steps.)
4
2
Used to check the operation of sensor and detector
in the option cassette and the related circuit.
3
Used to check the operation of the load in the
option tray and the control circuit.
5
1
Used to check the operation of the display (LED),
LCD in the operation panel, and control circuit.
2
Used to check the operation of the heater lamp and
the control circuit.
3
Used to check the operation of the copy lamp and
the control circuit.
6
1
Used to check the operation of the loads (clutches
and solenoids) in the paper transport system and
the control circuit.
2
Used to check the operation of each fan motor and
its control circuit.
7
1
Used to set the aging operation conditions.
6
Used to set the cycle of intermittent aging.
8
Used to set the display of the warm-up time.
8
1
Used to check and adjust the operation of the
developing bias voltage in each copy mode and the
control circuit.
2
Used to check and adjust the operation of the main
charger grid voltage (high mode) in each copy
mode and the control circuit.
3
Used to check and adjust the operation of the main
charger grid voltage (low mode) in each copy mode
and the control circuit.
10
Used to check and adjust the operation of the
developing bias voltage in each printer mode and
the control circuit.
11
Used to check and adjust the operation of the main
charger grid voltage (high mode) in each printer
mode and the control circuit.
12
Used to check and adjust the operation of the main
charger grid voltage (low mode) in each printer
mode and the control circuit.
13
Used to check and adjust the operation of the
developing bias voltage in FAX mode and the
control circuit.
8
14
Used to check and adjust the operation of the main
charger grid voltage (high mode) in FAX mode and
the control circuit.
15
Used to check and adjust the operation of the main
charger grid voltage (low mode) in FAX mode and
the control circuit.
9
1
Used to check and adjust the operation of the load
(motor) in the duplex section and the control circuit.
4
Duplex motor RPM setting
5
Used to adjust the timing of switching from normal
rotation to reverse rotation or from reverse rotation
to normal rotation of the duplex motor.
10
0
Used to check the operation of the toner motor and
its control circuit.
14
0
Used to cancel excluding the self-diag U2/PF
troubles.
16
0
Used to cancel the self-diag U2 trouble.
17
0
Used to cancel the self diag “PF” trouble.
21
1
Used to set the maintenance cycle.
22
1
Used to check the counter value of each section.
2
Used to check the total numbers of misfeed and
troubles. (When the number of misfeed is
considerably great, it is judged as necessary for
repair. The misfeed rate is obtained by dividing this
count value with the total counter value.)
3
Used to check the misfeed positions and the
number of misfeed at each position.
(When the number of misfeed is considerably
great, it can be judged as necessary for repair.)
4
Used to check the total trouble (self diag) history.
5
Used to check the ROM version of each unit
(section).
6
Used to print each key operator setting, the
account information, and the machine adjustment
values.
7
Used to display the key operator code. (Use when
the customer key operator code is forgotten.)
8
Used to display the original, staple counter.
9
Used to check the number of use of each paper
feed section. (the number of prints)
10
Used to check the system configuration.
11
Used to display the FAX send/receive counter
(FAX reception and print counter).
12
Used to check the misfeed positions and the
number of misfeed at each position.
(When the number of misfeed is considerably
great, it can be judged as necessary for repair.)
13
Used to display the CRUM type.
19
Used to display the scanner counter in the network
scanner mode.
24
1
Used to clear the misfeed counter, the misfeed
history, the trouble counter, and the trouble history.
(The counters are cleared after completion of
maintenance.)
2
Used to clear the number of use (the number of
prints) of each paper feed section.
3
Used to clear the number usage data of the stapler,
RSPF, and scanning.
4
Used to reset the maintenance counter.
5
Used to reset the developer counter.
(The developer counter of the DV unit which is
installed is reset.)
6
Used to clear the copy counter.
7
Used to clear the OPC drum (membrane decrease)
correction counter. (This simulation is executed
when the OPC drum is replaced.)
Code
Function
Main
Sub