AR-M256/M257/M258/M316/M317/M318/5625/5631 SIMULATION 8 - 56
* Execution of the simulation which performs communication with the
PCL board is inhibited until Notice Page storage is completed. (Only
when the serviceman call error occurs.)
* In the other case than the serviceman call error, entering the simula-
tion is inhibited during the system check operation is displayed.
Note: Executable only when the PCL is installed.
Operation/procedure
1.
Press the [START] key.
“PLEASE SEND DATA” is displayed.
2.
Data are sent from the PC (MS-DOS) by use of “fcopy” command
(FCOPY: file name). (Refer the “[7] FLASH ROM VERSION UP
PROCEDURE”)
Used to overwrite and check the flash device while displaying its
process status.
After completion, the result is displayed.
3.
Press the [CA] key to cancel the simulation and reset.
* Execution of the simulation which performs communication with the
PCL board is inhibited until Notice Page storage is completed. (Only
when the serviceman call error occurs.)
* In the other case than the serviceman call error, entering the simula-
tion is inhibited during the system check operation is displayed.
Operation/procedure
Press the [START] key.
Each ROM on the PCL board is checked and the result is displayed.
The display of “---” is changed to “CHECKING,” “OK,” or “NG” accord-
ing to the message number included in the continuation command.
When the simulation is completed normally, “COMPLETE” is displayed.
(No display for abnormal completion.)
Since only the devices installed to the PCL board are checked when
the simulation is started, the display may not be changed from “---.”
(No message is sent for an uninstalled device.)
Key operations on each display
(Initial display)
Pressing the [INTERRUPT] key shifts the display to the previous menu.
Pressing the [CA] key leads to resetting. The [C] key and the [CUS-
TOM SETTINGS] key are invalid. (Beep sound).
(Execution display)
During execution, the [INTERRUPT] key, the [C] key, and the [CA] key
are invalid. (Beep sound). Pressing the [CUSTOM SETTINGS] key
produces a valid sound only.
(Check end display)
After execution, the [INTERRUPT] key and the [C] key are invalid.
(Beep sound). Pressing the [CA] key leads to resetting. Pressing the
[CUSTOM SETTINGS] key produces a valid sound only.
After completion of the simulation, reset the machine.
Operation/procedure
1.
Press the [START] key.
The confirmation dialogue is displayed.
2.
Select “1: YES” with the 10-key and press the [START] key.
1: YES (Cleared)
2: NO (Not cleared) (Default)
If there is no abnormality after Clear operation, “COMPLETE” is dis-
played. If there is any abnormality, “ERROR” is displayed.
* Execution of the simulation which performs communication with the
PCL board is inhibited until Notice Page storage is completed. (Only
when the serviceman call error occurs.)
* In the other case than the serviceman call error, entering the simula-
tion is inhibited during the system check operation is displayed.
Note: Executable only when the PCL is installed.
Operation/procedure
1.
Press the [START] key.
The confirmation dialogue is displayed.
2.
Select “1: YES” with the 10-key and press the [START] key.
1: YES (Cleared)
2: NO (Not cleared) (Default)
If there is no abnormality after Clear operation, “COMPLETE” is dis-
played. If there is any abnormality, “ERROR” is displayed.
67-14
Purpose
Flash ROM version up
Function
(Purpose)
Used to check write/comparison of flash programs.
Section
Printer
Item
Operation
(Flash Device)
PROGRAM
BOOTROM
PS KANJI FONT
ESC/P KANJI FONT
OPTION FONT
(Processing state)
RECEIVE
ERASE
WRITE
VERIFY
67-15
Purpose
Operation test/check
Function
(Purpose)
Used to check the validity of the ROM on the PCL
board and the result is displayed.
Section
Printer
Item
Operation
67-17
Purpose
Data clear
Function
(Purpose)
Used to clear the printer section setting.
(NVRAM clear)
67-18
Purpose
Data clear
Function
(Purpose)
Used to clear the data area for FLASH ROM Network
Scanner Application.