AR-M256/M257/M258/M316/M317/M318/5625/5631 SIMULATION 8 - 26
Operation/procedure
Used to set the count up number (1 or 2) when an A3/WLT paper
passes through.
For the drum counter and the developer counter, double count is
employed unconditionally.
(Target counter selection)
Used to set the count up number of the selected counter.
Operation/procedure
Select the destination with the 10-key.
By changing the destination, some other setting items may be changed.
Operation/procedure
Enter the set value with the 10-key and press the [START] key.
If the trial scanner counter value is less than 500, the trial mode setting
can be repeatedly made. If the scanner trial counter value is 500 or
more, the trial mode setting cannot be made.
When the scanner is not set and the scanner trial counter value is less
than 500, if “1” is entered in SIM26-10, the trial mode setting is started.
If “0” is entered in SIM26-10, the trial mode setting is canceled.
After recognition of the scanner, the trial mode setting cannot be made.
(Entering “1” is invalid and a beep sound is produced.)
When this setting is made, the machine must be reset after canceling
the simulation. When “1: Trial mode start” is selected, the scanner
function is valid. If “0: Trial mode cancel” is selected, the scanner func-
tion is invalid.
When setting is invalid (when the scanner is recognized or the scanner
trial counter value is 500 or more) in the key operations of the trail
mode setting, an invalid sound (beep sound) is made. In the other
case, a valid sound is made.
* When the scanner trial counter value is changed from 500 or more to
less than 500, the trail setting is changed from “END” to “SETTING
START.”
Note: Executable only when the PCL/SCANNER is installed.
Operation/procedure
The current setup is displayed with ON or OFF.
Enter an input (20 digits) of the E-MAIL RIC soft key with the 10-key
and press the [START] key, and the collating result is displayed with OK
or NG.
After canceling the simulation, if OK, the E-MAIL RIC function is
enable; if NG, the E-MAIL RIC function is disabled.
This setting must be reset after the simulation cancel.
* If recognition is OK, the E-Mail RIC can be set to Enable. If the FAX
is installed, however, the operation cannot be made actually.
Note: Executable only when the PCL/NIC is installed.
26-5
Purpose
Setting
Function
(Purpose)
Used to set the count mode of the total counter and the
maintenance counter.
Item
Specifications
Counter
Item
Content
1
TOTAL COUNTER
Total counter
2
MAINTENANCE COUNTER
Maintenance counter
Item
Content
Setting range
Default
1
SINGLE COUNT
Single count
1-2
2
2
DOUBLE COUNT
Double count
26-6
Purpose
Setting
Function
(Purpose)
Used to set the specifications depending on the
destination.
Item
Specifications
Destination
Item
Content
Setting
range
Default
0
JAPAN
Japan
0-14
0
1
SEC
SEC
2
SECL
SECL
3
SEEG
SEEG
4
SUK
SUK
5
SCA
SCA
6
SEF
SEF
7
INEG
EX inch series
8
ABEG
EX AB series
9
INEF
EX inch series (FC)
10
ABEF
EX AB series (FC)
11
CHINESE
China
12
TAIWAN
Taiwan AB
13
SEEG2
SEEG2
14
TAIWAN2
Taiwan China
NANCE
SIMULATION 26-6
26-10
Purpose
Setting
Function (Purpose)
Network scanner trial mode setting
Section
Scanner
Item
Content
Default
0
END
Trail mode cancel
0
1
START Trial
mode
start
26-12
Purpose
Setting
Function
(Purpose)
Used to input the Software Key for E-MAIL RIC.
Section
E-MAIL RIC
Item
Specifications