AR-M256/M257/M258/M316/M317/M318/5625/5631 SIMULATION 8 - 34
• When each count correction setting is "enable" in Sim44-2/3 and
each correction is reaching specified count, these are displayed.
Operation/procedure
The following data are displayed.
* The value before entry of SIM is displayed. (It is not revised in real
time.)
If sim entry is just after power turned on, the display value is all 0.
Operation/procedure
Set a toner density control correction value of the specified DV count.
Operation/procedure
The following data are displayed. (The displayed value is the previous
print correction value.)
TH AREA5
Current correction value of the
environment correction area 5
(Grid/DVB correction)
0
0
TH AREA6
Current correction value of the
environment correction area 6
(Grid/DVB correction)
0
0
TH AREA7
Current correction value of the
environment correction area 7
(Grid/DVB correction)
0
0
TH AREA8
Current correction value of the
environment correction area 8
(Grid/DVB correction)
0
0
44-14
Purpose
Adjustment/Setup/Operation data output/Check
(Display/Print)
Function
(Purpose)
Used to display the environment (temperature,
humidity) correction information.
Item
Operation
TH AREA
Current environment area
TMP DATA
Detection temperature of sensor (C°)
HUD DATA
Detection humidity of sensor (%)
Item
Content
Default
25cpm
31cpm
SIMULATION 44-9
SIMULATION 44-14
44-16
Purpose
Setting
Function
(Purpose)
The correction value for the toner density reference
value corresponding to the DV count value is set
individually for 145mm/s and 122mm/s (for the 31-
sheet machine and the 25-sheet machine).
Section
Image process
(Photoconductor/Developing/Transfer/Cleaning)
Item
Operation
Item
Content
Default
1
0K
Toner concentration control
correction value
(145mm/s of 31-sheet model)
55
2
2K
3
4K
4
10K
5
20K
6
40K
7
60K
8
80K
9
100K
10 0K
Toner concentration control
correction value
(122mm/s of 25-sheet model)
60
11 2K
12 4K
13 10K
14 20K
15 40K
16 60K
17 80K
18 100K
19 0K
Toner concentration control
correction value
(122mm/s of 31-sheet model)
50
20 2K
21 4K
22 10K
23 20K
24 40K
25 60K
26 80K
27 100K
44-17
Purpose
Adjustment/Setup/Operation data output/Check
(Display/Print)
Function
(Purpose)
Used to display the toner density control reference
value.
Section
Image process
(Photoconductor/Developing/Transfer/Cleaning)
Item
Operation
TARGET
Toner concentration control reference value
DEV REF
Developer adjustment value
LIFE
Toner container life correction value (SIM 44-16)
SIMULATION 80-19