AR-5127 SIMULATION 8 - 30
Operation/procedure
Select the mode with the arrow keys, enter the adjustment value with
the 10-key, and press the [OK] key.
When the [START] key is pressed, a print is made and the display
returns to the mode selection menu.
Input the offset for the copy adjustment.
Setup of various copy conditions: Similar to the normal copy mode.
Use of [SPECIAL FUNCTION] key, [JOB STATUS] key, and [INTER-
RUPT] key is inhibited.
Open the OC cover, and put the lead edge/sub scan automatic adjust-
ment chart on the OC. (Keep the OC cover open.)
Place the chart correctly on the OC reference position. (If not, a correct
adjustment cannot be made.)
If the adjustment is normally completed, the adjusted value is dis-
played and written into the EEPROM. In case of an abnormality, "ERR"
is displayed and the value is not written into the EEPROM.
If no adjustment is made because of an abnormality, "---" is displayed.
Operation/procedure
Adjust and set FAX document read magnification ratio, read and print
the document.
Note: Executable only when the FAX is installed.
Operation/procedure
After the adjustment/setting of FAX print magnification ratio, read and
print the document.
Note: Executable only when the FAX is installed.
Operation/procedure
Set the FAX auto reduction magnification ratio (0 to 15%).
Note: Executable only when the FAX is installed.
48-2
Purpose
Adjustment
Function
(Purpose)
Used to adjust the scanner mode magnification ratio
(main/sub scanning direction).
Section
Image processing
Item
Picture quality
(Initial screen)
(Input screen)
(Executing screen)
Display items
Content
Setting
range
Default
1:F-R
Main scanning magnification
ratio adjustment
1-99
50
2:SCAN
Sub scanning magnification
ratio adjustment
3:SPF(SIDE1)
SPF surface sub scan
magnification ratio
4:SPF(SIDE2)
SPF back surface sub scan
magnification ratio
48-3
Purpose
Adjustment
Function
(Purpose)
Used to adjust the lead edge/sub scan magnification
ratio automatically.
Item
Operation
(Initial screen)
(Execution screen)
(Normal end screen)
(Abnormal end screen)
Sim48-2 SCANNER MAG
1:F-R
50
2:SCAN 50
3:SPF(SIDE1) 50
1/2
50
Sim48-3 READ AUTO
PRESS OK KEY EXEC
Sim48-3 READ AUTO
EXEC
Sim48-3 READ AUTO
RRC-A [ 32]
OC Center [ 53]
MirSpeed [ 58]
PRESS OK KEY EXEC
Sim48-3 READ AUTO
RRC-A [ ERR]
OC Center [ ERR]
MirSpeed [ ---]
PRESS OK KEY EXEC
48-8
Purpose
Adjustment
Function
(Purpose)
FAX magnification ratio adjustment (read)
Related soft
SW
SW76-1 to 8, SW77-1 to 8
Adjustment magnification ratio
Adjustment
range
Adjustment
unit
OC read main scanning
magnification ratio
1 – 128 –
255%
0.1%
increment
OC read sub scanning
magnification ratio
SPF read main scanning
magnification ratio
SPF read sub scanning
magnification ratio
48-9
Purpose
Adjustment
Function
(Purpose)
FAX magnification ratio adjustment (print)
Related soft SW
SW78-1 to 8, SW79-1 to 8
Adjustment magnification ratio
Adjustment
range
Adjustment
unit
Main scanning magnification ratio
1 – 128 –
255%
0.1%
increment
Sub scanning magnification ratio
48-10
Purpose
Adjustment
Function
(Purpose)
FAX auto reduction magnification ratio (print).
Related soft SW
SW25-1 to 4