AR-5127 SIMULATION 8 - 10
*1. The negative value of the set value corresponds to the grid high
output voltage.
*2. The set values can be selected from the above 8 patterns only.
*3. The selected pattern determines the grid high voltage and the grid
low voltage.
If, for example, the grid high voltage is set to –480V (pattern 1), the
grid low voltage is –350V.
Operation/procedure
After selecting the mode, enter the adjustment value and press the
[OK] key, and output will be made for 30sec.
The input value is in the increment of –25V.
(
∗
) Linked with the destinations of SIM 26-6.
Linked with the auto exposure mode of SIM 46-19-1.
* SUPER PHOTO (5:) cannot be executed.
When [OK] or [START] key is pressed, a caution buzzer sounds.
(Only the adjustment value can be entered.)
*1. The negative value of the set value corresponds to the grid high
output voltage.
*2. The set values can be selected from the above 8 patterns only.
*3. The selected pattern determines the grid high voltage and the grid
low voltage.
If, for example, the grid high voltage is set to –480V (pattern 1), the
grid low voltage is –350V.
Operation/procedure
After selecting the mode, enter the adjustment value and press the
[OK] key, and output will be made for 30sec.
The minimum increment is 2V.
The result of (Set value – 199) / 2 is stored in the EEPROM.
When reading a value from the EEPROM, the value of (EEP value *2)
+ 200 is used as the set value.
Therefore, the set value entered must be an even number. If an odd
number is entered the entered odd 1 is displayed after
pressing [OK] key.
Operation/procedure
After selecting the mode, enter the adjustment value and press the
[OK] key, and output will be made for 30sec.
The input value is in the increment of –25V.
NO.
Set value
Grid High
Grid Low
1 480
–480V
–350V
2 505
–505V
–375V
3
530
–530V
–400V
4
555
–555V
–425V
5
580
–580V
–450V
6 605
–605V
–475V
7 630
–630V
–500V
8 655 –655V
–525V
8-3
Purpose
Adjustment/Operation test/check
Function
(Purpose)
Used to check and adjust the operation of the main
charger grid voltage (low mode) in each copy mode
and the control circuit.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Photo conductor
(Initial screen)
(Input/Selection screen) (Executing screen)
Display items
Content
Setting
range
Default
1:AE
AE (
∗
)
1-8
3 (–400V)
2:TEXT
Character
5 (–450V)
3:TEXT/PHOTO
Character/Photo
5 (–450V)
4:PHOTO
Photo
5 (–450V)
5:SUPER PHOTO *
Super photo
Disabled
6:TONER SAVE
Toner save
2 (–375V)
NO.
Set value
Grid High
Grid Low
1 480
–480V
–350V
2 505
–505V
–375V
3
530
–530V
–400V
4
555
–555V
–425V
5
580
–580V
–450V
6 605
–605V
–475V
7 630
–630V
–500V
8 655 –655V
–525V
Sim8-3 MHV(L) COPY
1:AE 3
2:TEXT 5
3:TEXT/PHOTO 5
1/2
Sim8-3 MHV(L) COPY
5:SUPER PHOTO 3
EXEC [ 1- 8]
3
Sim8-3 MHV(L) COPY
5:SUPER PHOTO 3
EXEC
[ 1- 8]
3
8-10
Purpose
Adjustment/Operation test/check
Function
(Purpose)
Used to check and adjust the operation of the
developing bias voltage in each printer mode and the
control circuit.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Developer/Toner hopper
(Initial screen)
(Input/Selection screen) (Executing screen)
Display items
Content
Installation
range
Default
1:DENS1(600)
Density 1 (600dpi)
200-550
400 (–400V)
2:DENS2(600)
Density 2 (600dpi)
450 (–450V)
3:DENS3(600)
Density 3 (600dpi)
450 (–450V)
4:DENS4(600)
Density 4 (600dpi)
450 (–450V)
5:DENS5(600)
Density 5 (600dpi)
500 (–500V)
6:TS(600)
Toner save (600dpi)
350 (–350V)
7:DENS1(1200)
Density 1 (1200dpi)
Disabled
8:DENS2(1200)
Density 2 (1200dpi)
Disabled
9:DENS3(1200)
Density 3 (1200dpi)
Disabled
10:DENS4(1200)
Density 4 (1200dpi)
Disabled
11:DENS5(1200)
Density 5 (1200dpi)
Disabled
8-11
Purpose
Adjustment/Operation test/check
Function
(Purpose)
Used to check and adjust the operation of the main
charger grid voltage (high mode) in each printer mode
and the control circuit.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Photo conductor
(Initial screen)
(Input/Selection screen) (Executing screen)
Sim8-10 DV BIAS PRT
1:DENS1(600) 400
2:DENS2(600) 450
3:DENS3(600) 450
1/4
Sim8-10 DV BIAS PRT
5:DENS5(600) 500
EXEC [200-550]
500
Sim8-10 DV BIAS PRT
5:DENS5(600) 500
EXEC
[200-550]
500
Sim8-11 MHV(H) PRT
1:DENS1(600) 3
2:DENS2(600) 5
3:DENS3(600) 5
1/4
Sim8-11 MHV(H) PRT
5:DENS5(600) 7
EXEC [ 1- 8]
7
Sim8-11 MHV(H) PRT
5:DENS5(600) 7
EXEC
[ 1- 8]
7