AR-5127 SIMULATION 8 - 22
Operation/procedure
Input the set value with the 10-key and press the [OK] key.
Note: Executable only with CRU (DM models).
Operation/procedure
AMS mode is set when setting the pamphlet (center binding) function.
Operation/procedure
Input the set value with the 10-key and press the [OK] key.
Note: Executable only when the finisher is installed.
Operation/procedure
Input the set value with the 10-key and press the [OK] key.
Operation/procedure
Input the set value with the 10-key and press the [OK] key, and the
LCD contrast will be immediately changed and displayed.
Operation/procedure
Input the set value with the 10-key and press the [OK] key.
If a model different from CPM setup (22cpm or 27cpm) of BOOT is set,
a system error will occur after canceling the simulation.
Operation/procedure
Input the set value with the 10-key and press the [OK] key.
This setup varies in connection with SIM 26-6 (Destination setup).
26-38
Purpose
Setting
Function
(Purpose)
Used to set whether to stop when the drum life is
reached.
Item
Operation
Display items
Content
Setting range
Default
0:STOP
Stop
0-1
0
1:NON STOP
Non stop
26-41
Purpose
Setting
Function
(Purpose)
Used to set whether the automatic magnification ratio
select (AMS) is always ON or not when setting the
pamphlet (center binding) function.
Item
Operation
Display items
Content
Setting range
Default
0:OFF
AMS is not set
automatically.
0-1
0
1:ON
AMS is set automatically.
26-46
Purpose
Setting
Function
(Purpose)
Used to set whether to meet with the output direction of
images regardless of the mode when installing the
finisher.
Item
Operation
Display items
Content
Setting range
Default
0:OFF
Setting No
0-1
0
1:ON
Setting Yes
26-50
Purpose
Setting
Function
(Purpose)
Used to set whether to use the black/white reverse
function.
Item
Operation
Sim26-38 DRUM STOP
DRUM LIFE OVER 0
(0:STOP
1:NON STOP)
[ 0- 1]
0
Sim26-41 PAMPHLET
AMS MODE SET 0
(0:OFF 1:ON)
[ 0- 1]
0
Sim26-46 OUT DIR
OUT DIRECTION 0
(0:OFF 1:ON)
[ 0- 1]
0
Display
items
Content
Setting
range
Default
0:ON
Enable
0-1
0
1:OFF
Disable
26-54
Purpose
Setting
Function
(Purpose)
Used to set the PWM duty (brightness) at the center
value of the LCD contrast.
Item
Operation
Setting range 30-70
Default
50
26-57
Purpose
Setting
Function
(Purpose)
Used to set the model code.
Item
Operation
Display items
Setting range
Default
1:AR-265G
1-3
1
2:AR-265FG
3:AR-5127
26-60
Purpose
Setting
Function
(Purpose)
Used to set enable/disable of the FAX mode key when
FAX is not installed. (When FAX is installed, the FAX
mode is enabled regardless of this setup.)
Item
Operation
Sim26-50 B/W REV.
B/W REVERSE 0
(0:ON 1:OFF)
[ 0- 1]
0
Sim26-54 LCD DUTY
LCD PWM DUTY 0
[ 30- 70]
0
Sim26-57 MACHINE
MACHINE CODE 1
(1:AR-265G
2:AR-265FG
1/2 [ 1- 3]
1
Sim26-60 FAX KEY
FAX KEY SETTING 0
(0:ON 1:OFF)
[ 0- 1]
0