AR-5127 SIMULATION 8 - 3
25
2
Used to make the initial setting of toner
concentration when replacing developer.
26
1
Used to set options. (This simulation is used to
make option setting when an option is installed.)
2
Used to detect the paper size.
3
Used to set the specifications of the auditor.
Setting must be made depending on the use
condition of the auditor.
5
Used to set the count mode of the total counter
and the maintenance counter.
6
Used to set the specifications depending on the
destination.
*10
Used to enter the Software Key for the Network
Scanner. (Setup is allowed only when the PCL
board is installed.
*12
Used to input the Software Key for E-MAIL RIC.
*14
Used to input the Software Key for the PS
extension kit.
*18
Used to set enable/disable of toner save operation.
20
Used to set the job separator paper exit mode.
22
Used to set the specification (language display) for
the destination.
30
Used to set the operation mode for CE mark.
35
Used to set the mode of trouble memory.
36
Used to set whether to stop when the maintenance
life is reached.
37
Used to set whether to stop when the developer
life is reached.
38
Used to set whether to stop when the drum life is
reached.
41
Used to set whether the automatic magnification
ratio select (AMS) is always ON or not when
setting the pamphlet (center binding) function.
46
Used to set whether to meet with the output
direction of images regardless of the mode when
installing the finisher.
50
Used to set whether to use the black/white reverse
function.
54
Used to set the PWM duty (brightness) at the
center value of the LCD contrast.
57
Used to set the model code.
60
Used to set enable/disable of the FAX mode key
when FAX is not installed. (When FAX is installed,
the FAX mode is enabled regardless of this setup.)
27
1
Used to set PC/MODEM communication trouble
(U7-00) detection Yes/No.
5
Used to enter the TAG No. of the copier.
30
1
Used to check the operation of sensors and
detectors in the sections other than the paper feed
section of the copier and the related circuit. (The
operation of sensors and detectors can be
monitored with the LCD.)
2
Used to check the operation of sensors and
detectors in the paper feed section and the related
circuits. (The operations of sensors and detectors
in the paper feed section can be monitored with
the LCD.)
40
1
Used to check the operation of the manual paper
feed tray paper size detector and the related
circuit. (The operation of the manual paper feed
tray paper size detector can be monitored with the
LCD.)
2
Used to adjust the manual paper feed tray paper
width detector detection level.
3
The AD conversion value of manual feed width
detection is displayed.
Code
Function
Main
Sub
41
1
Used to check the document size detection photo
sensor.
2
Used to adjust the detection level of the document
size photo sensor.
3
Used to check the light reception level and the
detection level of the original size detection photo
sensor.
4
Used to adjust the detection level of OC 20
degrees.
43
1
Used to set the fusing temperature in each
operation mode.
10
Used to set the paper feed cycle for postcard.
44
1
Used to make various setups in each mode of
process control.
34
Used to adjust the transfer current value.
35
Correction temperature setup when correcting the
ambient temperature.
40
Used to set the rotating time before toner supply.
46
2
Used to adjust the copy exposure level.
*7
Used to adjust individually the copy exposure
level. (Super photo)
9
Used to adjust individually the copy exposure
level. (Character)
10
Used to adjust individually the copy exposure
level. (Character/Photo)
11
Used to adjust individually the copy exposure
level. (Photo)
12
FAX exposure level adjustment (batch)
13 to
16
FAX exposure level adjustment (individual)
18
Used to adjust the copy contrast. (Inclination)
19
Used to change the image quality in the exposure
mode.
20
Used to correct SPF exposure.
30
Used to set the AE limit.
48
1
Used to adjust the copy mode magnification ratio
(main scanning direction, sub scanning direction).
2
Used to adjust the scanner mode magnification
ratio (main/sub scanning direction).
3
Used to adjust the lead edge/sub scan
magnification ratio automatically.
8
FAX magnification ratio adjustment (read)
9
FAX magnification ratio adjustment (print)
10
FAX auto reduction magnification ratio (print).
50
1
Used to adjust the copy lead edge position.
5
Used to adjust the print image position (top
margin) on the print paper in the print mode.
6
Used to adjust the print image position (top
margin) on print paper in the copy mode. (SPF/
RSPF)
8
FAX lead edge adjustment (read)
9
FAX lead edge adjustment (print)
10
Used to adjust the print image center position.
(Adjustment can be made for each paper feed
section.)
12
Used to adjust the print image center position.
(Adjustment can be made for each document
mode.)
51
1
Used to adjust the OPC drum separation pawl ON
time.
2
Used to adjust the contact pressure of paper onto
the resist roller in each section (copier paper feed
section, duplex paper feed section, SPF paper
feed section). (When the print image position
varies greatly for the paper or when a lot of paper
jam troubles occur, the adjustment is required.)
Code
Function
Main
Sub
Summary of Contents for AR-5127
Page 93: ......