AR-5127 SIMULATION 8 - 8
Operation/procedure
Press the [OK] key.
ON/OFF operation of the heater lamp is repeated 5 times in an interval
of 500ms.
Operation/procedure
Press the [OK] key.
The copy lamp lights up for 10 sec.
When 10 sec passed, the copy lamp is turned OFF.
Operation/procedure
The names of the loads which can be operated are displayed. Select
the load to be checked with the 10-key.
The motor for 10sec, the solenoid ON for 500msec, OFF for 500msec.
(20 times)
The lift-up motor operates only when the tray is opened.
Operation/procedure
The names of the loads which can be operated are displayed. Select
the load to be checked with the key.
The selected fan motor is highlighted and it rotates for 10sec.
Operation/procedure
Select with the 10-key.
Press [CA] key, and the simulation will be terminated and copying will
be made with the set contents.
5-2
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of the heater lamp and the
control circuit.
Section
Fixing (Fusing)
Item
Operation
(Initial screen)
(Executing screen)
5-3
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of the copy lamp and the
control circuit.
Section
Optical (Image scanning)
Item
Operation
(Initial screen)
(Executing screen)
6
6-1
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of the loads (clutches and
solenoids) in the paper transport system and the
control circuit.
Section
Paper transport (Discharge/Switchback/Transport)
Item
Operation
(Initial screen)
(Executing screen)
1:LUM1
1st cassette lift-up motor
2:CPFC1
1st cassette pick-up solenoid
3:CPFS1
1st cassette paper feed clutch
4:MPFS
Manual feed pick-up solenoid
5:RRC
Resist roller clutch
6:PSPS
Separation pawl solenoid
7:OGS
Paper exit gate switching solenoid
8:LUM2
2nd cassette lift-up motor
9:CPFC2
2nd cassette pick-up solenoid
10:CPFS2
2nd cassette paper feed clutch
Sim5-2 HEATER LAMP
PRESS OK KEY EXEC
Sim5-2 HEATER LAMP
EXEC
Sim5-3 COPY LAMP
PRESS OK KEY EXEC
Sim5-3 COPY LAMP
EXEC
Sim6-1 OUTPUT CHECK
1:LUM1 4:MPFS
2:CPFC1 5:RRC
3:CPFS1 6:PSPS
1/2 EXEC
Sim6-1 OUTPUT CHECK
7:OGS 10:CPFS2
8:
LUM2
11:TRC2
9:CPFC2
2/2
EXEC
8
11:TRC2
2nd cassette transport roller clutch
12:LUM3
3rd cassette lift-up motor
13:CPFC3
3rd cassette pick-up solenoid
14:CPFS3
3rd cassette paper feed clutch
15:TRC3
3rd cassette transport roller clutch
16:LUM4
4th cassette lift-up motor
17:CPFC4
4th cassette pick-up solenoid
18:CPFS4
4th cassette paper feed clutch
6-2
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of each fan motor and its
control circuit.
Section
Others
Item
Operation
(Initial screen)
(Executing screen)
1:VFM
Only the fusing fan operates
2:DCFM&DCFM2
Power cooling fan, power cooling fan 2
operations
3:VFM&DCFM&DCFM2
Fusing fan, power cooling fan, and power
cooling fan 2 are operated at the same time.
7
7-1
Purpose
Setting/Operation test/check
Function
(Purpose)
Used to set the aging operation conditions.
Item
Operation
1:AGING
Aging enable/disable setting
2:MISFEED
Jam detection enable/disable setting
3:FUSING
Fusing operation enable/disable setting
The fusing temperature is not controlled. The heater is
not turned ON.
4:INTERVL
Intermittent setting (Valid only when set to AGING.)
5:WARMUP
Warm-up save setting
The machine goes into the ready state only by
shading, disregarding fusing and process control.
After going into the ready state, normal control is
performed.
6:DV CHK.
Developing unit detection enable/disable setting
Sim6-2 FAN MOTOR
1:VFM
2:DCFM&DCFM2
3:VFM&DCFM&DCFM2
EXEC
2
Sim6-2 FAN MOTOR
1:VFM
2:
DCFM
&DCFM2
3:VFM&DCFM&DCFM2
EXEC
2
Sim7-1 AGING SET.
1:AGING 4:INTERVL
2:
MISFEED
5:WARMUP
3:FUSING 6:DV CHK.
2
Summary of Contents for AR-5127