background image

USER

   MANUAL

 

 

P-1

P-1

Summary of Contents for P-1

Page 1: ...USER MANUAL P 1 P 1 ...

Page 2: ... change without notice SGM and all affiliated companies disclaim liability for any injury damage direct or indirect loss consequential or economic loss or any other loss occurred by the use of inability to use or reliance on the information contained in this manual The SGM logo the SGM name and all other trademarks in this document pertaining to SGM services or SGM products are trademarks owned or...

Page 3: ...y level 11 Error Indicator 11 Shortcuts 11 Connecting to a DMX control device 11 Connecting a wireless transmitter 11 Disconnecting a wireless transmitter 12 Signal priority 12 Configuring the device for DMX control 12 About DMX 12 DMX start address 12 Set edit DMX address 12 DMX modes 13 Using standalone operation 13 Setting a static color manually 13 Fixture properties 13 Factory default 13 Effe...

Page 4: ...prevent burns and fire Do not look directly at the light source from close range Take precautions when working at height to prevent injury due to falls For Permanent Outdoor Installations POI ensure that the fixture is securely fastened to a load bearing surface with suitable corrosion resistant hardware For a temporary installation with clamps ensure that the quarter turn fasteners are turned ful...

Page 5: ... and a shortened life expectancy Do not place the battery in microwave ovens high pressure containers or on induction cookware Immediately discontinue use of the battery if while using charging or storing the battery emits an unusual smell feels hot changes color or shape or appears abnormal in any other way Only charge the battery mounted in the fixture with the built in charger Do not use a thir...

Page 6: ...er frames 19 45 63 x12 elliptical 12 x63 elliptical Built in wireless DMX and programmable standalone programs Fully RDM compliant Very low power consumption Rubber feet meant for delicate surfaces and prevents fixture from sliding The fixture also offers running for up to 12 hours in standard operation mode the P 1 can easily be configured to provide an even output over longer periods of time The...

Page 7: ...nsure that It is situated away from public thoroughfares and protected from contact with people It is not immersed in water or exposed to high pressure water jets It has adequate ventilation Transportation Always use the supplied packaging or suitable flight case for transportation and storage Never carry the fixture by connected cables or wires Preparing for installation The P 1 may be installed ...

Page 8: ... the two 1 4 turn sockets in the base Insert the fasteners into the base bracket and turn both levers a full1 4 turn clock wise to lock 4 Working from a stable platform hang the fixture on a truss or other structure Tighten the clamp 5 Install a safety wire that can bear at least 10 times the weight of the fixture The safety wire attachment point is designed to fit a carabiner 6 Verify that there ...

Page 9: ... see figure 6 with a power connector or similar with a maximum of 20 A to ensure the correct ingress protection IP rating The P 1 can also run on battery power up to 12 hours with the possibility to extend the battery time up to 24 hours The fixture must be grounded earthed and able to be isolated from AC power The AC power supply must incorporate a fuse or circuit breaker for fault protection For...

Page 10: ...xtension When using the P 1 running on battery power the estimated battery capacity is up to 12 hours The P 1 can be configured to extend the battery time for up to 24 hours by dimming the output accordingly Go to MENU SETTINGS BATTERY EXTENSION The battery extension time set in the menu only applies to a fixture with fully charged batteries The battery time is reduced when using the P 1 in cold e...

Page 11: ...ashing if the paired trans mitter is out of range If no transmitter is paired the symbol will be off Current input type When DMX is displayed The fixture responds to data received through cabled DMX When CRMX is displayed The fixture responds to data received through wireless DMX Current DMX address Displays the current DMX address The DMX address is altered directly from this view The next availa...

Page 12: ...f the same type have the same DMX address they will behave identically Address sharing can be useful for diagnostic purposes and symmetrical control For independent control each P 1 must be assign its own address have a DMX start address set For example if the first P 1 is set to 3ch DMX mode with a DMX address of 10 it uses the channels 10 11 and 12 Then the following P 1 in the DMX chain should ...

Page 13: ...am go to ENTER MANUAL STOP PROGRAM Using standalone operation Figure 8 Standalone operation Setting a static color manually The P 1 can be configured to display a predefined static color or color preset To set up a static color based on RGBW mixing select ENTER MANUAL QUICK COLOR Note that once the MANUAL QUICK COLOR settings are changed the fixture will by default be set to automatically start in...

Page 14: ...correction The P 1 offers seamless CTC color temperature correction control from 2000 Kelvin 10000 Kelvin The color temperature can also be modified via color presets when in manual operation see above Beam angle The P 1 is equipped with a fixed 10 beam angle The beam angle can be manipulated in various ways by using one of the optional magnetic holographic filters 19 45 63 12 elliptical and 4 8 w...

Page 15: ...og off Sends Log off command to the CRMX System Enable disable Enable disable wireless DMX functionality Bridge Display strength of the wireless connection Status Displays wireless connection status Startup mode Select startup mode Default operating mode when fixture is powered on 1 DMX factory default 2 Stand alone 3 Quick Color Startup program Select startup program Stand alone program 1 2 or 3 ...

Page 16: ...dress 0x00E0 GET SET DMX Personality Mode 0x00E1 GET DMX Personality Description 0x1000 GET SET Identify 0x1001 SET Reset Device 0x0200 GET Sensor Definition 0x0201 GET SET Sensor Value 0x0082 GET SET Device Label 0x0081 GET Manufacturer Label 0x8060 GET Serial Number 0x0080 GET Device Model Description 0x0400 GET SET Device Hours 0x0051 GET Parameter Description PID Actions Name 0x0501 GET SET Di...

Page 17: ... accessories visit www sgmlight com or contact your local SGM dealer Filter frames The P 1 features various optional magnetic holographic filter frames Medium angle 19 Wide angle 45 Elliptical wide angle horizontal 63 x12 Elliptical wide angle vertical 12 x63 The filter frames install easily using magnets built in to the frames and fixtures To install them position the filter frame in front of the...

Page 18: ...ironment and installation Therefore it is recommended to do frequent check ups the first few weeks of operation to see how often cleaning is necessary Maintenance Service Figure 12 SGM Firmware tool Troubleshooting Problem Potential cause s Remedies Fixture does not respond or appears to be completely dead No power to the fixture Confirm that the power is switched on confirm that the cables are pl...

Page 19: ...614 83061214 Filter Frame MediumAngle BL WH P N 83061140 83061240 Filter Frame WideAngle BL WH P N 83061141 83061241 Filter Frame Elliptical Horz wide angle BL WH P N 83061142 83061242 Filter frame Elliptical Vert wide angle BL WH P N 83061147 83061247 Barndoor 4 way P 1 series BL WH P N 83061138 83061238 Barndoor 8 way P 1 series BL WH P N 83061139 83061239 Flightcase for 4 pcs P 1 P N 82051009 F...

Page 20: ...20 SGM Light A S Sommervej 23 8210 Aarhus V Tel 45 70 20 74 00 info sgmlight com www sgmlight com ...

Reviews: