DMX modes
The P-1 operates in different DMX modes. All detailed DMX charts are available at www.sgmlight.com under the respective products,
or upon request via [email protected].
Standalone operation can be used when the fixture is not connected to a control device. It can be programmed with a series of up
to 24 scenes, playing continuously in a loop. Up to three stand-alone programs can be defined and run from the menus, and one of
the programs can be set to run by default whenever the fixture is powered on.
Each of the three available stand-alone programs contains 24 user-definable
scenes with its own RGB and shutter settings.
Each scene has a definable fade-in time for the transition from one color to the
next, and a wait (static) time of up to 120 minutes and 59 seconds.
To record a stand-alone program, press ENTER → MANUAL → EDITOR.
The standalone mode of the fixture’s startup is enabled by pressing:
ENTER → SETTINGS → STARTUP MODE → SELECT STARTUP MODE →
STANDALONE.
To select the fixture’s startup program, go to:
ENTER → SETTINGS → STARTUP MODE → STARTUP PROGRAM.
The chosen program will run its length cyclically whenever the fixture is
powered on.
To run an internal program, go to:
ENTER → MANUAL → RUN PROGRAM.
To stop an active internal program, go to:
ENTER → MANUAL → STOP PROGRAM.
Using standalone operation
Figure 8: Standalone operation
Setting a static color manually
The P-1 can be configured to display a predefined static color or color preset.
To set up a static color based on RGBW mixing, select ENTER → MANUAL → QUICK COLOR.
Note that once the MANUAL → QUICK COLOR settings are changed, the fixture will, by default, be set to automatically start in quick
color mode whenever it is powered on. This can be reset through the menu SETTINGS → STARTUP MODE → SELECT STARTUP
MODE.
Since firmware version 2.22, the P-1 includes a number of color presets accessible via display. To set up a color preset, select:
ENTER → MANUAL → COLOR PRESETS
The current quick color program or selected color presset can always be stopped by selecting:
ENTER → MANUAL → STOP PROGRAM
See “Control menu” on page 14 for detailed information.
Factory default
When restoring factory defaults in the P-1, the following will be set:
• DMX address = 1
• DMX mode = Default mode (6 channel)
• Startup mode = DMX
•
Flip screen = Off
• Power loss function = Battery backup
• RDM device label set to = Fixture type name
• Internal program reset
Effects
Colors and LED Panels
The P-1 features 8 high-power 12.5W RGBW LEDs, divided in two individually controllable
panels (left and right). Each panel represents a cluster of four lenses.
The fixture can operate in RGB calibrated mode which ensures that colors are compatible
Fixture properties
Figure 9: P-1 Pixel segments
Summary of Contents for P-1
Page 1: ...USER MANUAL P 1 P 1 ...