WARNING! Always secure an elevated P-1 with a safety wire.
Fasten a safety wire (not shown) between the load-bearing support structure and the safety wire attachment point on the device.
The safety cable (not included in the package) must:
• Bear at least 10 times the weight of the device (SWL).
• Have a minimum gauge of 4 mm.
• Have a maximum length (free fall) = 30 cm (12 in.).
CAUTION!
• Always use a safety wire of a grade AISI 316 steel.
• Make sure the slack of the safety wire is at a minimum.
• Never use the yoke for secondary attachment.
Ceiliing / Wall mount
The P-1 can be installed with an optional ceiling / wall mount. The ceiling / wall mount is design to fit the base bracket on the P-1.
To install the ceiling / wall mount:
1. Loosen the lock screw on the ceiling / wall mount.
2. Install the ceiling / wall mount to the surface.
3.
Position the fixture over the four slide locks and slide to the locked position.
4. Fasten the lock screw.
Safety wire attachment point
Figure 4: Safety wire attachment point
Connecting AC power
The P-1 can operate on any 100-240 V, 50/60 Hz AC mains power supply.
Connect the fixture to AC power using the supplied 8 mm cable (see figure 6) with a power connector or similar, with a maximum of
20 A, to ensure the correct ingress protection (IP rating). The P-1 can also run on battery power, up to 12 hours with the possibility to
extend the battery time up to 24 hours.
The fixture must be grounded/earthed and able to be isolated from AC power. The AC power supply must incorporate a fuse or
circuit breaker for fault protection.
For a temporary outdoor installation, the mains cable must be fitted with a grounded connector intended for exterior use.
For permanent installation, have a qualified electrician wire the mains cable directly to a suitable branch circuit. The ingress
protection (IP) rating of the TRUE1 connector and junction’s must be suitable for the location.
After connecting the P-1 to power, run the on-board test by selecting TEST → AUTOMATED TEST in the menu to ensure that the
fixture and each LED are functioning correctly. Please see “Control menu” on page 14.
CAUTION!
Do not open the fixture to replace the supplied power cable.
Do not connect the fixture to an electrical dimmer system, as doing so may cause damage.
PLEASE NOTE:
The protective caps must be securely mounted on any unused DMX or power connector, in order to maintain the IP65-rating.
The fixture must be grounded/
earthed and be able to be isolated
from AC power. The AC power
supply must incorporate a fuse or
curcuit breaker for fault protection.
Color
Black
White
green/yellow
Conductor
live
neutral
ground (earth)
Symbol
or
L
N
Wire
Figure 6: Connecting AC Power/P-1 power cable 8 mm
Figure 5: P-1 Ceilling / Wall mount
Summary of Contents for P-1