14
Control menu
Level 1
Level 2
Level 3
Level 4
Function
Mode
Select mode
-
-
Select DMX mode.
Manual
Quick color
Red
0-255
Static quick color - red mix (0-255). Sets fixture to quick
color startup mode.
Green
0-255
Static quick color - green mix (0-255). Sets fixture to quick
color startup mode.
Blue
0-255
Static quick color - blue mix (0-255). Sets fixture to quick
color startup mode.
White
0-255
Static quick color - white mix (0-255). Sets fixture to quick
color startup mode.
Full color calib.
On or off
Select between color calibrated or RAW color mode.
Color preset
Intensity
0-255
Dimmer.
Color
White 3200 K
Color preset #
White 5600 K
White 10000 K
Congo
Red
Green
Blue
Orange
Light green
Pink
Light blue
Purple
Neon green
Magenta
Cyan
Yellow
CTC
Run program
1, 2 or 3
-
Runs internal sequence 1, 2 or 3.
Stop program
-
-
Stops current running internal sequence or Quick Color.
Editor
Program
-
Edits scenes.
across the range of SGM fixtures. However, the P-1 also offers the ability to operate in RAW mode with full control of each color.
Color temperature correction
The P-1 offers seamless CTC (color temperature correction) control from 2000° Kelvin - 10000° Kelvin. The color temperature can
also be modified via color presets when in manual operation (see above).
Beam angle
The P-1 is equipped with a fixed 10° beam angle. The beam angle can be manipulated in various ways by using one of the optional
magnetic holographic filters (19°, 45°, 63°/12° elliptical), and 4/8 way barndoors.
Individual fixture settings
Flipping the display
If the fixture is installed hanging upside down, it may be useful to flip the display so that it is easier to read.
To flip the display, press ENTER and select SETTINGS → FLIP DISPLAY, or press the up and down buttons on the control panel at
the same time.
Setting the OLED display saver
By default the OLED display dims down after a short period when the control panel is in the root menu and not in use. The display can
also be set to turn off completely, ideal when a pitch-black environment is required. Pressing any key will always turn on the display
or restore it to normal brightness.
To configure the display settings, press ENTER → SETTINGS.
NOTE: To avoid the risk of display deterioration caused by long term use, it is recommended to select the setting → DISPLAY OFF.
Summary of Contents for P-1
Page 1: ...USER MANUAL P 1 P 1 ...