16
Supported RDM functions
The P-1 features support for various RDM functions, as per the ANSI E1.20 standard.
RDM (Remote Device Management) is a protocol enhancement to USITT DMX512 that allows bi-directional communication between
the fixtures and the controller over a standard DMX line. This protocol will allow configuration, status monitoring, and management.
A RDM enabled controller is required to control the supported parameters. See the tables below for supported RDM functions.
RDM functions
RDM
Name
Sensor Type
Mainboard Temp.
Temperature
LED Left
Temperature
LED Right
Temperature
Humidity
Other
AC power connected
Contacts
Battery PCT (percentage)
Other
Battery charging
Contacts
Battery voltage
Voltage
Wireless signal strength
Other
Name
Sensor Type
Wireless paired
Other
Red LED Hours Pixel 1
Time
Green LED Hours Pixel 1
Time
Blue LED Hours Pixel 1
Time
White LED Hours Pixel 1
Time
Red LED Hours Pixel 2
Time
Green LED Hours Pixel 2
Time
Blue LED Hours Pixel 2
Time
White LED Hours Pixel 2
Time
PID
Actions
Name
0x00F0
GET / SET
DMX Start Address
0x00E0
GET / SET
DMX Personality / Mode
0x00E1
GET
DMX Personality Description
0x1000
GET / SET
Identify
0x1001
SET
Reset Device
0x0200
GET
Sensor Definition
0x0201
GET / SET
Sensor Value
0x0082
GET / SET
Device Label
0x0081
GET
Manufacturer Label
0x8060
GET
Serial Number
0x0080
GET
Device Model Description
0x0400
GET / SET
Device Hours
0x0051
GET
Parameter Description
PID
Actions
Name
0x0501
GET / SET
Display Level, 0=OFF, 1 and above=ON
0x0500
GET / SET
Display Invert
0x8626
SET
CRMX Log Off
0x8631
GET / SET
Battery Extension Hours
0x0090
SET
Factory Defaults
0x0120
GET
Slot Info
0x0121
GET
Slot Description
0x0122
GET
Default Slot Value
0x8637
GET / SET
Bridge ENABLE=1 DISABLE=2
0x8620
GET / SET
Led freq (197647Hz) / value
0x8634
GET / SET
Quick color feature 0=HOLD 1=WHITE
2=OFF 3=Q COLOR
0x8636
GET
Active Error
Please note:
The RDM controller communicates with the fixtures to show only the available options for each RDM function. The table is subject to change without notice.
Sensors
RDM enables various sensor readouts for remote device monitoring. See the table below for sensors and sensor types.
Please note:
The RDM controller communicates with the fixtures to show only the available sensors for this fixture.
The table is subject to change without notice.