PERMANENTLY CONNECTING POWER & DATA
Figure 18: Connecting DMX and AC Power in G-7 BeaSt POI
DMX-in and DMX-out are in the same cable. See more in figure about the SGM POI DMX cable.
For permanent installations, have a qualified electrician to wire the mains cable directly to a suitable branch circuit.
The junction’s ingress protection (IP) rating must be suitable for the location.
For a temporary installation, the mains cable may be fitted with a grounded connector intended for exterior use.
PLEASE NOTE!
• Cat5e compliant cable is suitable for the transmission of DMX 512 with RDM.
• Up to 32 fixtures can be connected to the same DMX link. Additional fixtures will overload the link.
• The last fixture must always be fitted with a DMX termination plug to the fixture’s DMX out.
• SGM fixtures provide a passive DMX Thru signal as DMX out, instead of an active output signal.
Max. 32 units/DMX line
DMX 512 / Cat5e
Compatible Cable
1
2
XX
SGM
SGM
SG
Shield
Wire
Color
White
Red
Conductor
Black
Yellow
Ground
DMX IN: Data -
DMX IN: Data +
DMX OUT: Data -
DMX OUT: Data +
SGM POI DMX Cable
Shield / GND
Standard Junction Box
(by Others)
Black / Live
White / Nuetral
Green & Yellow / Ground
Shield / Ground
White / DMX in / Data -
Red / DMX in / Data +
Yellow / DMX Out / Data +
Black / DMX out / Data -
Voltage Barrier
Power
Shield / GND
End Junction Box
(by Others)
Black / Live
White / Nuetral
Green & Yellow / Ground
Shield / Ground
White / DMX in / Data -
Red / DMX in / Data +
Yellow / DMX Out / Data +
Black / DMX out / Data -
Voltage Barrier
120 Ohm Resistor
installed between
Data + & -
DMX Data -
DMX Data +
DMX 512 / Cat5e
Compatible Cable
in Conduit (by others)
To Luminaire
To Luminaire
Power Cable
in Conduit
(by others)
Power Cable
in Conduit
(by others)
Data Cable
in Conduit
(by others)
DMX Data -
DMX Data +
Data Cable
in Conduit
(by others)
Splice Link / Connection
Fixture Power Lead
Fixture Data Lead
Fixture Data Lead
Fixture Power Lead
Fixture Power Lead
Fixture Data Lead
DMX 512 / Cat5e
Compatible Cable
in Conduit (by others)
Junction Box
Power
Power