29
SI 580E DIN SIZE WEIGHING CONTROLER
www.sewhacnm.co.kr
“Check-Sum” detection selection (Under F62-01 setting, only)
F64
●
0
Check-Sum Not Use
1
Check-Sum Use
Under Stream Mode select the way transmit data protocol/frame (extended port)
F65
●
0
Transmit by Protocol
1
Transmit by frame (in case of using specific utility)
Caution: In case of “Transmit by frame” & under 14400bps setting(F61), the speed of
system will be slow.
DATA Transference Mode selection (Extended Serial port)
F66
●
0
Weighing Data will be transferred continuously
1
Single time data transference, Whenever the weight is steady over than
Empty range.
2
Single time data transference, first weight steady point over than Empty
range.
3
Data transference, Whenever “Print” key input
DATA Transference Format selection (Extended Serial port)
F67
●
0
Format 1 (recommended when use external display)
1
Format 2. (Format 1 + ID No.)
2
Format 3.
3
CAS Format
Print Mode selection (Extended Serial port)
F68
●
0
Manual Print : Whenever “Print” key input.
1
Auto print (When the first Steady point over “EMPTY” range
or Whenever “Print” key input.)
2
Auto print (Whenever Steady status at over the range of “EMPTY”
or Whenever “Print” key input.)
3
Auto print(After weighing finished)
Refer the F21-3,4,5 setting
■ Other Setting Mode
EMPTY Range setting
F80
10
You can set “EMPTY” Range.
Ex) “0” setting : When Net Zero, “Zero” status lamp is ON.
“200” setting : Under “200”, “Zero” Status lamp is ON.
Minimum Analog Output Setting
F81
Minimum analog output value is able to adjust to be 4mA or 0V.
Maximum Analog Output Setting
F82
Maximum analog output value is able to adjust to be 20mA or 10V.