26
│ 3 Using the system
3.4.1
Starting a measurement
Note:
The quality of the
correlation result
also depends on the general
noise level at the start of a measurement.
●
Wherever possible, try to start a measurement when there is
no loud sound interference in the background (e.g. no passing
vehicles, extraction from house connections).
The main view is open. The
Start measurement
button is vis-
ible (fig. 9, image above).
●
Tap the
Start measurement
button when the general noise
level is suitable. The measurement will start. The
Stop meas-
urement
button will appear.
3.4.1.1
Starting the measurement after configuring pipe sections
Once the pipe sections have been configured, the calculation
data must be reset before a new measurement can be started.
The main view is open. The
Start measurement
button is not
visible (fig. 9, image below).
1. Tap the
Reset
button. The
Start measurement
button will
appear.
2. Tap the
Start measurement
button when the general noise
level is suitable. The measurement will start. The
Stop meas-
urement
button will appear.
3.4.1.2 Continuing measurement
Measurements can be continued under the following conditions:
●
The measurement has been stopped.
●
The pipe sections have not been changed.
●
The calculation data has not been
reset
.
To continue the measurement, it must be restarted.