4 Settings
│
49
4.3.2
Type
The displayed extreme value can be either the quietest or the
loudest noise of a measurement.
The options are:
●
MIN
The lowest measurement value (minimum) is displayed.
●
MAX
The highest measurement value (maximum) is displayed.
SEWERIN recommends: Select
MIN
for leak detection.
4.3.3
Hearing protection
There is a hearing protection threshold for acoustic playback of
the noise. The hearing protection activates when the set hearing
protection threshold is exceeded. Hearing protection can work
in two ways.
The options are:
●
Muted
The noise is muted so that it can just about be heard above
the hearing protection threshold.
●
Silent
The noise cannot be heard above the hearing protection
threshold.
For information about setting the hearing protection threshold,
please refer to section 3.5 on page 25.
4.3.4
Activation keys
Note:
This setting determines how the activation keys on both the re-
ceiver and the sensor area on the carrying rod are operated.
The activation keys / sensor area can be operated in two differ
-
ent modes.