4
Drive units with optional ASEPTIC / ASEPTICplus design
Mechanical Installation
4.6.2
Tightening torques when using optional ASEPTIC
plus
design
Blanking plugs
Tighten the blanking plugs optionally included in the delivery by SEW-EURODRIVE with
2.5 Nm:
Example
The following figure shows an example. The number and position of cable entries
depends on the variant you have ordered.
WARNING
Burns caused by hot surfaces.
Severe injuries.
• Let the units cool down before touching them.
Type of screw fitting
Content
Size
Part number
Screw plugs
hexagon
(made of stainless steel)
10 pcs
M16 x 1.5
1 824 734 2
10 pcs
M25 x 1.5
1 824 735 0
4768590091