![SEW DRC.-...-DAC Operating Instructions Manual Download Page 102](http://html1.mh-extra.com/html/sew/drc-dac/drc-dac_operating-instructions-manual_1250005102.webp)
102
Operating Instructions – Electronic Motor DRC.-..-DAC
7
SBus (CAN) communication via interface adapter
Operation of MOVITOOLS
®
MotionStudio
7.4.4
Communication parameters for SBus
The following table describes the [Basic setting] for the SBus communication channel:
The following table describes the [Advanced setting] for the SBus communication
channel:
Communication parameters
Description
Information
Baud rate
Transmission speed with which
the connected PC communicates
with the unit in the network via the
communication channel.
•
Adjustable values (permitted
total cable length):
•
500 kBd (50 m)
(Default)
•
1 MBd (25 m)
•
All connected units must
support the same baud rate.
Communication parameters
Description
Information
Parameter telegrams
Telegram with a single parameter
Used to transfer a
single
parameter
of a unit.
Multi-byte telegrams
Telegram with several parameters Used to transfer the
complete
parameter set of a unit.
Timeout
Waiting time in [ms] that the
master waits for a response from
the slave after it has made a
request.
•
Default setting:
•
100 ms (parameter
telegram)
•
350 ms (multi-byte
telegram)
•
Increase the value if not all
units are detected during a
network scan.
Retries
Number of request retries after
the timeout is exceeded
Default setting: 3
00