Operating Instructions – Electronic Motor DRC.-..-DAC
113
8
Overview of power section parameters
Parameters
8.2.2
Parameters that can be changed
Storage location
Setpoints/ramp generators
INFORMATION
The following parameters are stored in the DRC
motor.
If the motor is replaced, for example for service
purposes, changes made to these parameters must
be made again.
Index
Parameter name
MOVITOOLS
®
MotionStudio
Display
(Range / factory setting)
MOVILINK
®
scaling
Power section parameters \ setpoints/ramp generators \ setpoint monitoring
Setpoint stop function
8578.0
Setpoint stop function
•
0 = Off
•
1 = On
8579.0
Stop setpoint
160 – 500 rpm
1 digit = 0.001 rpm
8580.0
Start offset
– 0 – 30 – 500 [rpm]
1 digit = 0.001 rpm
Power section parameters \ setpoints/ramp generators \ speed ramps
Stop ramps
8476.0
Stop ramp t13
0.0 – 2.0 – 2000.0 [s]
1 digit = 0.001 s
8477.0
Emergency stop ramp t14
0.0 – 2.0 – 2000.0 [s]
1 digit = 0.001 s
Ramp monitoring functions
8928.0
Ramp monitoring
•
0 = Off
•
1 = On
Power section parameters \ setpoints/ramp generators \ motor potentiometer
8486.0
Ramp t3 up
0.2 – 20.0 – 2000.0 [s]
1 digit = 0.001 s
8487.0
Ramp t3 down
0.2 – 20.0 – 2000.0 [s]
1 digit = 0.001 s
8488.0
Save last setpoint
•
0 = No
•
1 = Yes
Motor
Electronics
cover