![SEW DFD11B Manual Download Page 59](http://html1.mh-extra.com/html/sew/dfd11b/dfd11b_manual_1250019059.webp)
Manual – DFD11B DeviceNet Fieldbus Interface
59
6
The Common Industrial Protocol (CIP)
DeviceNet Characteristics
Connection
object
• In the connection object the process- and parameter connections are defined.
• Class code: 05
hex
Class
None of the class attributes are supported.
Instance 1 ... 3
Supported ser-
vices
Instance
Communication
1
Explicit message
2
Polled I/O
3
Bit-Strobe I/O
Attribute
Access
Name
1
Get
State
2
Get
Instance type
3
Get
Transport Class trigger
4
Get
Produce connection ID
5
Get
Consume connection ID
6
Get
Initial com characteristics
7
Get
Produced connection size
8
Get
Consumed connection size
9
Get/Set
Expected packet rate
12
Get
Watchdog time-out action
13
Get
Produced connection path len
14
Get
Produced connection path
15
Get
Consumed connection path len
16
Get
Consumed connection path
17
Get
Production inhibit time
Service Code [hex]
Service Name
Instance
0x05
Reset
X
0x0E
Get_Attribute_Single
X
0x10
Set_Attribute_Single
X
0
0
I