Manual – DFD11B DeviceNet Fieldbus Interface
57
6
The Common Industrial Protocol (CIP)
DeviceNet Characteristics
• Coding of attribute 5 "Status":
• Coding of the "extended device status " (Bit 4 ... 7):
Supported ser-
vices
Bit
Name
Description
0
Owned
Controlling connection is active
1
-
Reserved
2
Configured
Configuration complete
3
-
Reserved
4 ... 7
Extended Device Status
→
Table "Coding of the extended device status"
8
Minor Recoverable Fault
Minor fault that can be remedied
9
Minor Unrecoverable Fault
Minor fault that cannot be remedied
10
Major Recoverable Fault
Major fault that cannot be remedied
11
Major Unrecoverable Fault
Major fault that cannot be remedied
12 ... 15
-
Reserved
Value [binary]
Description
0000
Unknown
0010
At least one faulty I/O connection
0101
No I/O connection established
0110
At least one I/O connection active
Service Code [hex]
Service Name
Instance
05
Reset
X
0E
Get_Attribute_Single
X
0
0
I